Sequoia / Tahoe Series User Manual California Instruments
62 M447352-01 REV-A
13
Output Voltage
Monitor - C
Analog
Output
0-7.07 V(RMS)
Signal outputs for output phase C for monitoring
the waveform of the command signal of the
output amplifier.
14 ISO_COM Return Return
Common Ground: Pins 4, 9, and 14 are
internally connected.
15 N/C N/C N/C N/C
Table 3-21: Analog Interface Connector
3.8.5 System Relay
A single row six pole terminal block (Figure 3-16) is located on the rear panel for remote control of Leader
/ Auxiliary configurations and Emergency Stop.
FOLLOWER and FCOM are used to remote control each system to configure for Leader or Follower
operation. When 24V DC is applied to the FOLLOWER and FCOM, the system is configured in
FOLLOWER operation. When 24V DC is removed, the unit operates in LEADER mode.
ESTOP and ECOM are used to remote control an Emergency shut off switch. This connection is required
to create an OR-ed operation of more than one –ES switch. When 24V DC is applied, the unit’s output is
Enabled (ON). When 24V DC is removed, the unit’s output is disabled (OFF). Note that ESTOP
connection is required for each individual chassis. ESTOP results in disabling voltage directly to the
amplifiers.
Pin Name Description
1 FOLLOWER
24VDC is applied to set the unit to either Leader unit or Follower
mode. Connection is made to Leader Chassis only.
2 FCOM Follower Common.
3 ESTOP 24V DC Enables unit’s Output and 0V DC Disables the unit’s Output
4 ECOM ESTOP Common.
5 AUX1 Reserved
6 AUX2 Reserved
Table 3-22: Leader Select and Emergency Stop Switch
Figure 3-16: FOLLOWER and ESTOP interconnect at the rear panel