UPS + Isolation User Manual
© 2020 AMETEK Electronic Systems Protection | Technical Support: 1-800-645-9721 | surgex.com
Model #: ABCE1442-11R / Part #:UPS-1440-Li-ISO
Rack Mount
UPS
Specifications
Front
Panel Controls
•
Po wer
On/Off
• Test
•
Load Leve l L ED
Gauge
•
Battery Ch arge L ED
Gauge
•
Voltage Mana ger Boost
LED
•
Voltage Output On
LED
•
Voltage Mana ger Bu ck
LED
•
On Battery
LED
•
Rep lace Batter y
LED
•
Over load
LED
•
Fault Co de
LED
•
System Over Te mp erature
LED
Rear
Panel
Information
and Controls
•
Integrated Switched Power Distribu tion
Unit
(Requires SNMP
/
Web
Card)
•
Configuration Manager DIP
Switches
•
Comm un ica tion s Ma nager DB9 Port , USB
Port
•
Circuit Bre aker ( AC an d
DC)
•
AC Inlet
Module
•
Comm un ica tion Opt ion Slot: SNMP
/
Web Card,
Isolated
Rela y Contacts Card, or Re mote Of f
Card
•
DC External Battery Ca bine t
Connector
•
Fan (For ced
Cooling)
Internal
Batteries
•
User Hot-S wappable (See Instruction
Manual)
•
Type: 12 Volt, High Rate
23W
•
Qua ntit y: 4
Batteries
•
Rec harge Time: 6 Hours to 80 %, 24 Hours to Full
Charge
(For I ntern al Batter ies
Only)
Environmental
• Temperature: 0 -
+40
℃
(32
to
104
℉
)
Operating
-20 to
60
℃
(-40
to
140
℉
)
Shipment/
Stora ge
• Humidity:
5 to 90 % Non- Condensing ( Operat ing,
Shipment/Storage)
• Altitude:
3,000m ( 10,000 ft) m ax.
Operating;
12,000 m (40,000 ft) max .
Shipment/Storage
Safety
Agency and
EMC
Compliance:
All Units are L isted by UL an d Marked With the UL/cUL
Marking
Standard
UPS:
Products
Listed
to:
•
UL1 778 5th
Edition
•
CS A 22.2 Nos.
107.3-14
Products in
Comp lianc e
with:
•
FCC- Part 1 5, Subp art B, Section s 15.107b &
15.109b
Cla ss A Dig ital
Device*
•
CISPR11:2 009, A1; 2010, Class
A*
•
IEC61 000-4-2, Ele ctrost atic
Discharge
•
IEC61 000-4-3, Radiated Electro magn etic Fiel d
Immunity
•
IEC61000-4-4, Electrical Fa st Tran sient/ Burst
Immunity
•
IEC61 000-4-5, Surge
Immunity
•
IEC61 000-4-6, I mmunity to Conducted Ra dio
Frequency
Disturbances
•
IEC61 000-4-8, Power Frequ ency Magnetic Fi eld
Immunity
•
IEC61000-4-11, Voltage Dip s, Sh ort Interru ption s
and
Voltage
Variations
*Note: Class B is Ava ila ble as an
Option
Pleas e Cons ult Your Surge X Sales
Representative
RoHS
Compliance:
All Produ cts (Standar d and Medi cal) are Ro HS
Compliant
1440
VA MODELS TYPICAL RUN-TIMES
(MINs)
NOI SE REJECTION-IS OLATI ON: With unit under po wer and an ANSI/IE EE C62.41 Cat. A pulse applied either nor mal or co mmon mode at the input,
the
noise output voltage will be less than
10V nor mal mode an d le ss t han 0 .5 V co mmon mo de in all f our qu adrants ( CM- NM, NM- NM, CM- CM,
NM-CM).
SURGE VOLTAGE WITHSTAND CAPABILITY: Tested under po wer to ANSI/IE EE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A
-
6000 V @ 200
amps,
0.5 usec riset ime, 10 0 k HZ decay,
Cat. B
-
6000 V @ 500 a mps, 0.5 use c risetime, 1 00 kHZ
decay.
Warranty/Suppo rt: SurgeX warrants the electronics and transformers used in its uninterruptible po wer managers to be free from defect s in material s and
work
manship for
a
period of five
years
from
the date
of shipment. Batteries
are
warranted for
a
period of two
years
from
the date
of
shipment. For service
or
support
on
any SurgeX product, please contact SurgeX Technica l
Support at (800) 645-9721 or visit the SurgeX website at
www.surgex.com.
Battery Life Disclaimer: SurgeX
’
s standard
battery warranty applies only
to UPS and
UPS products which
are
continuously
connected
to AC mains
power,
except during utility power
outages. Products which are regularly and intentionally disconnected fro m AC mains power will experience battery discharge/charge cy cles potentially far more numerous than those for which the
battery wa s designed. As a result, products used in such applications will experience substantiall y
reduced
battery life. For
that reason,
SurgeX
’
s standard
battery warranty
does
not apply
for applications in which
the UPS or
UPS product
is
regularly
and
intentionally disconnected from AC main s po wer. SurgeX UPS and UPS products used in such applications shall receive a 90
day warranty on