Security Plus II
User’s Manual
Online UPS with Isolation Transformer
2kVA / 3kVA / 4kVA / 5.2kVA / 6kVA / 8kVA / 10kVA

Questions and Answers

  • C
    cmarshAug 13, 2025
    What to do if Ametek Powervar Security Plus II UPS is overloaded?
    • L
      Lori OliverAug 14, 2025
      If the Ametek UPS is overloaded, remove some of the connected devices from the UPS output to reduce the load. This should resolve the overload condition.
  • K
    Karen KelleyAug 17, 2025
    What to do if Ametek Powervar Security Plus II is overloaded and uses Bypass?
    • J
      Judith NelsonAug 17, 2025
      If your Ametek UPS is overloaded and devices are being fed directly by the electrical network via the Bypass, the solution is to remove excess loads from the UPS output.
  • M
    Mario HallAug 21, 2025
    What to do if Ametek Powervar Security Plus II shows fault code 14?
    • M
      mooretiffanyAug 21, 2025
      If fault code 14 is displayed on the Ametek UPS LCD, and the alarm beeps continuously, it indicates a short circuit on the UPS output. You should check the output wiring and the connected devices for a short circuit.
  • B
    Brandon OwensAug 25, 2025
    What to do if Ametek UPS is locked in Bypass mode after repetitive overloads?
    • T
      taylorcatherineAug 26, 2025
      If your Ametek UPS is locked in Bypass mode after repetitive overloads, and connected devices are fed directly by the mains, first remove excess loads from the UPS output. Then, shut down the UPS and restart it.
  • R
    Reginald CraigAug 28, 2025
    Why Ametek Powervar Security Plus II UPS battery backup time is short?
    • M
      meredithjordanAug 28, 2025
      There are a couple of reasons why your Ametek UPS battery backup time might be shorter than expected: * The batteries may not be fully charged. Charge the batteries for at least 7 hours and then check capacity again. * The batteries could be defective.
  • C
    Colleen MckaySep 1, 2025
    What to do if Ametek Powervar Security Plus II shows fault code 43?
    • J
      Jennifer SilvaSep 1, 2025
      If fault code 43 is shown on the Ametek UPS, the icon lights on the LCD display, and the alarm beeps continuously, it means the UPS is overloaded for too long and has become faulty, causing it to shut down automatically. Remove excess loads from the UPS output and restart it.
  • B
    Brittany GomezSep 5, 2025
    How to disable EPO function on Ametek UPS?
    • T
      Travis HudsonSep 5, 2025
      If the icon and the warning code flash on the Ametek UPS LCD display and the alarm beeps every second, it means the EPO (Emergency Power Off) function is enabled. To disable it, set the circuit to the closed position.
  • B
    Brandon SmithSep 9, 2025
    What to do if Ametek Powervar Security Plus II has no display?
    • M
      Manuel BishopSep 9, 2025
      If there is no indication and alarm on the front display panel of your Ametek UPS, even though the mains is normal, it could be due to the AC input power not being connected properly. Check if the input cable is firmly connected to the mains.

Summary

General Safety Instructions

Key User Safety Information

Crucial safety notes and operational guidance for users.

Compliance with Safety Standards

Details on safety, performance, EMI, and EMS standards followed.

Unpacking and Inspection

Product Inspection Procedures

Instructions for checking contents and unit condition post-delivery.

UPS Panel Layout

UPS Panel Component Identification

Identifies and describes the various ports and components on the UPS panel.

UPS Installation (Hardwire units only)

Hardwired Installation Overview

General guidance and precautions for installing hardwired UPS units.

UPS Wiring Diagram and Connection Guide

Visual guides for connecting UPS input and output wiring.

Required Circuit Protection Ratings

Recommended branch circuit breakers for UPS input and output protection.

Operation

UPS Control Button Functions

Explains the functions of each button on the UPS control panel.

LED Indicators and LCD Panel Information

Details LED indicators and LCD panel messages for UPS status.

Core UPS Operation Procedures

Step-by-step guide for turning on, off, and operating the UPS.

LCD Setting

Configuring Output Voltage and Frequency

Configuration of output voltage and frequency parameters via LCD.

Bypass and ECO Mode Settings

Settings for bypass voltage/frequency ranges and ECO mode.

Battery Backup and System Configuration

Configuration for battery backup time, hot standby, and charging current.

Operation Mode;Status Description

UPS Standard Operating Modes

Explains AC, ECO, and CVCF operating modes and their LCD displays.

UPS Special Modes and Fault Status

Details Battery Mode, Bypass Mode, Battery Test, and Fault Status.

Fault and Warning Codes

Comprehensive Fault Code Reference

Lists and explains all possible fault codes and their meanings.

Warning Indicators and Codes Guide

Describes warning icons, their flashing behavior, and associated codes.

Troubleshooting

Troubleshooting Common UPS Issues

A table to help diagnose and resolve common UPS symptoms and issues.

Storage and Maintenance

UPS Storage Recommendations

Recommendations for storing the UPS unit properly.

UPS Maintenance Safety and Procedures

Safety precautions and procedures for maintaining the UPS.

Warranty

Standard Warranty Terms

Outlines the standard warranty period and terms for the UPS.

Warranty Exclusions and Limitations

Lists conditions that void the warranty or are not covered.

Ametek Powervar Security Plus II Specifications

General IconGeneral
CategoryUPS
Input Voltage120 V
Output Voltage120 V
Frequency50/60 Hz
Output ReceptaclesNEMA 5-15R
ProtectionSurge