7.6.2 Hyd rau lic hose li nes
1 Am mann Ar ti cle No.
2 Ma nu fac tu rer/Month and year of ma nu fac tu re
3 Max. ope ra ting pres su re
The func tion of hy drau lic hose lines must be tested at reg u lar in -
ter vals (min i mum once a year) by an ex pert (with a knowl edge of
hy drau lics).
Hose lines must im me di ately be re placed in the fol low ing in -
stances:
Dam age to the outer layer to the in ner lin ing (abra sion marks,
cracks, cuts, etc.).
Brit tle ness of the outer layer (crack ing of hose cov er ing).
Un nat u ral de for ma tions of the hose line. This ap plies to both a
pressureless and pres sur ised con di tion (e.g. layer sep a ra tion,
blis ter for ma tion, crushed ar eas, kinks).
Leaks.
Dam age or de for ma tion of hose fit tings (im paired seal ing
func tion).
Hose slips out of the fit ting.
Cor ro sion of fit ting (de grad ing of func tion and strength).
Im proper in stal la tion.
Use bey ond the ex pi ry date of max. 6 ye ars.
LM75020000-2 HbmG gnu thci dreV nna mmA © 9102/01