12
Installation
Rev 2 – May 06 OMM223000015
2 Connect the control medium to the “IN” port using a quality thread
sealant such as Loctite ™ Pipe Sealant to the pipe thread connections -
8.62 bar (125 psi) maximum.
CAUTION
If the Valve is located in a hazardous area, the “VENT” port must be
connected by a pipe that vents outside the hazardous area.
3 Connect the “VENT” port depending on the type of control medium.
# Air – no connection is required but it should be protected from
contamination by an AMOT 4125 Vent Closure (refer to Fig 3) or a
tubing elbow bent downwards.
# Oil – connect to the sump.
# Gas – connect to system vent.
If required, an AMOT 4054 Trip Indicator can be fitted (Refer to manual