7
2.3 Safety checks
In the case of industrial or commercial use, it is recommended to carry out safety inspections of
the AmpliCube every 12-24 months. The older the unit, the more regular safety inspections are
recommended.
The technical inspections entail:
1. Checking the accompanying papers to make sure the user manual exists
2. Checking the equipment for completeness
3. Visual inspection
• for mechanical damage
• of all cables and connectors for damage
4. Functional safety
• Check of the output signals at a load resistance of 1 k (voltage)
• Check of the frequencies
• Check of the modulation depth
These safety checks may only be carried out by adequately trained staff and are to be documen-
ted.
2.4 Safety notes for the electrodes
Electrode suits (AmpliSkin and AmpliShort) and strip electrodes (AmpliStrap) may only be used in
the form delivered by the manufacturer. These must also be cared for and handled in accordance
with the care instructions.
For your own safety and that of the user of the AmpliTroden suits, the AmpliTroden/
electrodes must be checked for conductivity before each use and especially after
they have been washed. Insufficient conductivity hinders training success and can
be harmful to health. The measuring instructions provided for this (see section 8 of
this user manual) are to be followed. If you have any questions about how to check
the AmpliTroden/electrodes for their conductivity, please contact a member of staff
at amplitrain systems GmbH before use.
Please follow the care and cleaning instructions, otherwise the quality and functio-
nality of the product cannot be guaranteed. Training success can suffer from this.
Damage to the device or harm to health cannot be ruled out in such cases.
Apply plenty of the water to the silver-looking surfaces of the electrodes to ensure
optimum conductivity along the entire area. Otherwise, the product’s functionality
cannot be guaranteed. Training success can suffer from this. Damage to the device
or harm to health cannot be ruled out in such cases.
Please also ensure that - if the electrode is not worn directly on the skin - nothing disturbs the
current transmission from the electrode to the body. No insulating material may be worn between
the skin and the electrode, underclothing may not form any creases underneath the electrodes
and no clothing that has not been recommended by the manufacturer may be worn underneath
the electrodes.