American Security Products Co. ESL15 Operating Instructions Released Aug. 9, 2018
Revision A
Page 10 of 10
ESL15 Beep and LED Patterns
Beeper Sounds
o Standard Beep: A short, distinct beep
o Warble: A high-low-high-low beep-chain, sounds like “dee-del-dee-del-deee.”
Beeper Behavior
Beep Pattern Description
1 Beep - Response to any keystroke during input
- Notice when lock exits Penalty Lockout
4 Beeps
This indicates an incorrect code was entered. After four incorrect attempts, the logic will enter a
“penalty lockout” for 15 minutes. During this period, the lock will not accept any input. You must
wait for the penalty lockout to expire. The lock will Beep/Flash once when this period ends.
4 Beeps, Repeating
Open Period Alert after Time Delay.
6 Beeps
The lock is in Penalty Lockout. During this period, the lock will not accept any input. You must wait
for the penalty lockout to expire. The lock will Beep/Flash once when this period ends.
Short
Warble
3 high-low tones for about 2.5
seconds
Short “Good Combination Tone” indicates the input is accepted during a Combination Change
Long
Warble
13 high-low tones for about
10 seconds
- LongGood Combination Tone indicates the input is accepted at completion of a Combination
Change
- End of Time Delay Period
LED Behavior
LED On Description
1 Flash - Response to any keystroke during input
- Notice when lock exits Penalty Lockout
- Any time a beep is sounded
- With each high-note in the Warble Sounds
1 Flash, Repeating Once every 5 seconds without User Input, indicates Penalty Lockout
Rapid Flash Time Delay Period is counting
On Solid (3 Seconds) While lock is activated after successful code entry