T
Tracy CarrilloAug 19, 2025
What to do if my andrews RFF 13/175 Water Heater has high water temperature?
- AAnna WilsonAug 19, 2025
If the Andrews Water Heater detects a high water temperature (over 93°C), first, check the lower sensor to ensure it's fully inserted into the well and secured by the clip on the sensor wire. Then, check the readings of both the lower and upper sensors. If they are not within specifications, replace the sensor. If the sensors and wire harnesses are okay, replace the control board.