INSTALLATION AND SERVICE MANUAL
Please read and understand these instructions before commencing installation and leave this manual with the customer for future reference.
Andrews. Built to perform.
CLASSICflo Fan Flued range
Models RFF 13/175 and RFF 18/270
Issue 4 21042018

Questions and Answers

  • T
    Tracy CarrilloAug 19, 2025
    What to do if my andrews RFF 13/175 Water Heater has high water temperature?
    • A
      Anna WilsonAug 19, 2025
      If the Andrews Water Heater detects a high water temperature (over 93°C), first, check the lower sensor to ensure it's fully inserted into the well and secured by the clip on the sensor wire. Then, check the readings of both the lower and upper sensors. If they are not within specifications, replace the sensor. If the sensors and wire harnesses are okay, replace the control board.
  • I
    ijohnsonAug 23, 2025
    What to do if my andrews Water Heater detects flame before ignition?
    • M
      Mrs. Cynthia HooverAug 23, 2025
      If the Andrews Water Heater detects flame before ignition, check to ensure the gas valve has fully closed and that no voltage is present at the gas valve before the ignition cycle. Verify the wire positions on the wire harness are correct. If the gas valve is stuck open, it should be replaced.
  • J
    Justin BoyleAug 26, 2025
    What to do if my andrews RFF 13/175 detects flame after heating cycle completes?
    • J
      James EdwardsAug 26, 2025
      If the Andrews Water Heater detects flame after the heating cycle completes, check to ensure the gas valve has closed completely and that no voltage is present at the gas valve after the ignition cycle. Make sure the wire positions on the wire harness are correct. If the gas valve remains stuck open, replace it.
  • R
    ricedawnAug 27, 2025
    What to do if my andrews Water Heater shows maximum number of ignition recycles detected?
    • V
      Virginia OrtizAug 27, 2025
      If the Andrews Water Heater displays a 'Maximum number of ignition recycles detected' error, it means that the pilot flame is lost during the run cycle but then reestablished on the ignition cycle. Check the inlet gas pressure to ensure it does not drop below the minimum operating pressure specified on the rating label after the main gas valve opens. Verify that the gas pipe size to the water heater is adequate. Inspect the pilot shield position and the condition of the burners, cleaning or replacing them as needed. Check the pilot flame and observe the microamp output on the run cycle. Inspect the pilot tubing leading to the pilot and replace it if it is crimped or damaged. Replace the pilot if the wires, flame sensor, or electrode are damaged.
  • C
    Caitlyn HermanAug 30, 2025
    What causes AC line frequency error in andrews Water Heater?
    • T
      thomasfranklinAug 30, 2025
      If the Andrews Water Heater experiences an AC line frequency error, which indicates the signal is too noisy or the frequency is incorrect, check the line voltage frequency to the water heater and determine if there are wide fluctuations. If the problem persists, call an electrician. Ensure the water heater is on a separate electrical line.
  • H
    hbensonAug 31, 2025
    How to fix low flame sense on andrews RFF 13/175?
    • S
      Selena RodriguezSep 1, 2025
      If the Andrews Water Heater has a low flame sense, determine the flame sense current in the Service mode while the water heater is operating. If it is less than 1.0 microamps, check the pilot flame sense rod with emery cloth. If the problem persists, replace the pilot.
  • M
    Michelle WillisSep 3, 2025
    What causes flame rod shorted to ground in andrews RFF 13/175?
    • D
      Derrick VincentSep 3, 2025
      If the Andrews Water Heater has a flame rod shorted to ground, check to see if the flame sensor wire has bare spots touching metal parts or if the flame sensor rod is touching the pilot shield or other metal parts. Replace the pilot if the flame sense wire is damaged or the flame rod is bent.
  • D
    Dr. Ashley WhiteSep 5, 2025
    What to do if andrews RFF 13/175 Water Heater flame sensed out of normal sequence?
    • S
      Samantha RomanSep 5, 2025
      If the Andrews Water Heater displays a 'Flame sensed out of normal sequence', check to make sure the gas valve has closed completely. Ensure no voltage is present at the gas valve before or after the ignition cycle. Verify the wire positions on the wire harness are correct. If the gas valve is stuck open, replace it.
  • D
    Dawn MorganSep 7, 2025
    Why is DC output voltage unstable in andrews RFF 13/175 Water Heater?
    • B
      Brian SimpsonSep 7, 2025
      If the Andrews Water Heater experiences unstable DC output voltage, check the line voltage to the water heater for erratic readings. Also, inspect the wiring to ensure there are no shorts. If the power supply and wiring are okay, replace the control board.
  • S
    Sheila JacobsSep 9, 2025
    How to troubleshoot faulty upper sensor reading on andrews RFF 13/175 Water Heater?
    • C
      Cynthia RodriguezSep 9, 2025
      If the Andrews Water Heater indicates an upper sensor reading faulty, check the continuity of the wire harness to the upper sensor. If the wire harness is okay, replace the upper sensor.

Summary

General and Safety Information

Health and Safety Regulations

Duty of care for product safety and user information.

Installation

Gas and Electrical Connections

Procedures for connecting gas supply and mains electricity.

Wiring Diagram

Schematic representation of the heater's electrical connections.

Commissioning

CLASSICflo Fan Flued Commissioning Steps

Procedure for initial setup and lighting of the appliance.

User Safety Guide

Essential safety instructions for operating the water heater.

Operation

Burner Assembly Operation

Checking burner pressure and assembly status.

Servicing and Maintenance

Resetting Lockout Conditions

Procedure for clearing error codes and restoring operation.

Diagnostic Error Codes

Definitions and troubleshooting for error codes.

Fault Finding

Troubleshooting Common Faults

Guide to identifying and resolving operational issues.

andrews RFF 13/175 Specifications

General IconGeneral
Brandandrews
ModelRFF 13/175
CategoryWater Heater
LanguageEnglish