Angelo Po 0G1CP1G - Replacement of the Burner Nozzle; Replacement of the Pilot Light Injector; Decommissioning the Appliance

Angelo Po 0G1CP1G
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 16 -
C139607600_1.fm
IT
AUS
SDE
FR
ES
REPLACEMENT OF THE BURNER NOZZLE
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the door (A).
3 - Unscrew the nozzle (B) and replace it with the one
suitable for the type of gas in use (see table at
back of manual).
4 - Close the door (A).
REPLACEMENT OF THE PILOT LIGHT INJECTOR
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the door (A).
3 - Unscrew the union (B).
4 - Extract the nozzle (C) and replace it with the
one suitable for the type of gas in use (see
table at back of manual).
5 - Screw the union (B) back in place and close the
door (A).
DECOMMISSIONING THE APPLIANCE
Important
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work.
Never dump non-biodegradable materials,
lubricating oils and non-metallic compo-
nents (rubber, PVC, resins, etc.) in the envi-
ronment. Dispose of them in accordance
with the relevant legal requirements.