Up (+) and Down (-)
Used to increase/reduce the set point
temperature in steps of 1°C from 17 to 30 °C,
or in steps of 1°F (or 2°F) from 62 to 88°F (or
86°F).
NOTE:
The temperature can be shown in °F or °C. To
change units, press the + and - buttons at the
same time for 3 seconds.
ON/OFF
Starts/stops the air conditioning.
Display
Shows the set point temperature in COOL
mode. The room temperature is shown in DRY
and FAN mode.
Error codes
E1 Error on room temperature sensor.
E2
Error on evaporator temperature
sensor.
E4 Display communication error.
EC
Leakage of refrigerant detected (some
models).
Warning code
P1
The tank is full. Connect the drain
hose and drain o the water. Contact
the retailer if the fault persists.
NOTE:
If any of the above error codes are shown,
switch o the air conditioner and check for any
obstructions. Start the air conditioner. Switch
o the air conditioner and pull out the plug if an
error code is still shown. Contact an authorised
service centre or other qualied personnel.
COOL (cooling mode)
1. Continue pressing the MODE button until
the COOL status light goes on.
2. Set the required room temperature (set
point temperature) with the + and -
buttons. The temperature can be set from
17 to 30°C or from 62 to 88°F (or 86°F).
3. Press the FAN SPEED button on the remote
control to set the fan speed.
FAN (fan only)
1. Continue pressing the MODE button until
the FAN status light goes on.
2. Press the FAN SPEED button on the
remote control to set the fan speed. It is
not possible to set the temperature.
3. Do not lead the hose through the window.
DRY (dehumidication)
1. Continue pressing the MODE button until
the DRY status light goes on.
2. In this mode it is not possible to adjust
the set point temperature or fan speed.
The fan motor runs at low speed. Keep
doors and windows closed for best
dehumidication function.
3. Do not lead the hose through the window.
SLEEP/ECO
This function can only be enabled from the
remote control. When the SLEEP function is
enabled the set temperature increases by
1°C/2°F (or 1°F) after 30 minutes.
After another 30 minutes the set temperature
increases by another 1°C/2°F (or 1°F). The new
temperature is maintained for 7 hours, after
which the original set temperature is restored.
The SLEEP mode then nishes and the air
conditioner runs with the original settings.
NOTE:
This function cannot be used in FAN or DRY
mode.