EasyManua.ls Logo

APART REVAMP2250 - User Manual

APART REVAMP2250
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
REVAMP2250
Instruction manual
Question and Answer IconNeed help?

Do you have a question about the APART REVAMP2250 and is the answer not in the manual?

Summary

Safety First

General Safety Precautions

Essential safety guidelines for installation, operation, and handling of the amplifier.

Hearing Protection and Handling Warnings

Warning about high sound levels, hearing loss risks, and general handling precautions.

Important Operational Warnings

Critical Operational and Environmental Safety

Important warnings regarding operating environment, cover removal, input/output connections, and application limitations.

Amplifier Features

Key Amplifier Features

Lists key features like rack unit height, class-D modules, bridgeable channels, and output power.

Advanced Features and Protection

Details on input attenuators, protection circuits, mute buttons, and APC limiter function.

Connections Overview

Front Panel Interface

Explanation of front panel elements: overload LEDs, input gain, and DSP selector.

Rear Panel Input;Output Connectors

Details on various speaker outputs (Euroblock, Speakon) and audio input connectors.

Mains Power Inlet

Information regarding the connection of the mains power cord to the unit.

Operation Guide

Power Switch and Status Indicators

Explains the power switch, power LED, and status indicators for channel mute and signal presence.

Channel Status and Overload LEDs

Details on CLIP/OVERLOAD, LIMIT/MUTED, and SIGNAL LEDs for channel operation.

DSP Settings and Signal Routing

Overview of DSP settings and detailed descriptions of various audio signal routing modes.

DSP Mode Configurations

Explains bridged mode and combined DSP configurations for specific audio setups.

Important Information and Specifications

Cooling and Installation Requirements

Critical details on convectional cooling, rack mounting, ventilation, and ambient temperature.

Voltage Operation Configuration

Instructions on how to set the unit for 110/115 VAC operation using a wire jumper.

Technical Specifications

Comprehensive list of technical specifications including power, impedance, sensitivity, and frequency response.

System and Physical Specs

Details on cooling, power consumption, dimensions, net weight, and operating voltage range.

Summary

Safety First

General Safety Precautions

Essential safety guidelines for installation, operation, and handling of the amplifier.

Hearing Protection and Handling Warnings

Warning about high sound levels, hearing loss risks, and general handling precautions.

Important Operational Warnings

Critical Operational and Environmental Safety

Important warnings regarding operating environment, cover removal, input/output connections, and application limitations.

Amplifier Features

Key Amplifier Features

Lists key features like rack unit height, class-D modules, bridgeable channels, and output power.

Advanced Features and Protection

Details on input attenuators, protection circuits, mute buttons, and APC limiter function.

Connections Overview

Front Panel Interface

Explanation of front panel elements: overload LEDs, input gain, and DSP selector.

Rear Panel Input;Output Connectors

Details on various speaker outputs (Euroblock, Speakon) and audio input connectors.

Mains Power Inlet

Information regarding the connection of the mains power cord to the unit.

Operation Guide

Power Switch and Status Indicators

Explains the power switch, power LED, and status indicators for channel mute and signal presence.

Channel Status and Overload LEDs

Details on CLIP/OVERLOAD, LIMIT/MUTED, and SIGNAL LEDs for channel operation.

DSP Settings and Signal Routing

Overview of DSP settings and detailed descriptions of various audio signal routing modes.

DSP Mode Configurations

Explains bridged mode and combined DSP configurations for specific audio setups.

Important Information and Specifications

Cooling and Installation Requirements

Critical details on convectional cooling, rack mounting, ventilation, and ambient temperature.

Voltage Operation Configuration

Instructions on how to set the unit for 110/115 VAC operation using a wire jumper.

Technical Specifications

Comprehensive list of technical specifications including power, impedance, sensitivity, and frequency response.

System and Physical Specs

Details on cooling, power consumption, dimensions, net weight, and operating voltage range.

APART REVAMP2250 Specifications

General IconGeneral
RMS Power 4 ohms2 x 250 W
RMS Power 8 ohms2 x 150 W
RMS Power bridged 8 ohms1 x 500 W
Minimum Impedance Unbridged4 ohms
Minimum Impedance Bridged8 ohms
Signal to Noise Ratio> 100 dB
Damping Factor> 200
TypePower Amplifier
Frequency Response20 Hz - 20 kHz
Input Sensitivity1.4V
Input Impedance20 kohms
Protection CircuitsDC, Short circuit, Overload, Thermal
THD<0.05% (1kHz)