ELF
Compact Heat Meter
Technical description
For rmware versions 13.01 or higher
ISO 9001 PN-N-18001 ISO 14001
Question and Answer IconNeed help?

Do you have a question about the Apator ELF and is the answer not in the manual?

Apator ELF Specifications

General IconGeneral
Rated Current5A
Frequency50Hz
DisplayLCD
MountingDIN rail
Operating Temperature-25°C to +55°C

Summary

Product Subject

Design, Functionality, and Characteristics

Basic Specifications

Data Types and Measurement

Calibration, Configuration, and Service Data

Data affecting measurement accuracy and configuration of operating functions, adjustable by the user.

Data Archiving

Configurable data archiving for cycle 1, cycle 2, monthly, and annual records, including configuration options.

Heat Meter LCD Operating Guide

Metrological Test Procedure

Procedure to verify resolver correctness by comparing calculated heat energy per m³ to meter indication.

Remote Data Reading

Wired M-Bus and Pulse I/O Interfaces

Data reading with M-Bus based on PN-EN 13757-3:2005 and PN-EN 1434-3:2009, enabling primary/secondary addressing.

Warranty and Service Information

Marking and Ordering Guidelines