and time are saved in the calculator upon finishing the
editing of the last digit (tens of minutes).
Additional input type editing
To change the type of the additional input,
briefly push the P2 button when displaying the
impulse input type screen. As a result, the input
type will be changed to another type available.
Depending on the input number, it is possible to set the
following types of inputs:
– inactive input,
– impulse input with impulse frequency: dm
3
/imp, imp/
dm
3
, imp/kWh,
– alarm input,
– input for digital communication with sensor.
NOTE: In case of setting the output type other than
an impulse one in the menu, the impulse frequency
and serial number settings for the given input are not
displayed.
Conrmation of the edited parameters
When setting date and time, the parameters in the
calculator are updated immediately after the end of
editing.
In order to confirm the remaining values, go to the last
screen – confirmation of configuration group changes.
If there have been changes made to the current config-
uration, the APPLY option will appear on the screen. To
save the changed configuration, push and hold the P2
button until the screen displays „No rConF”. This means
that the calculator is already configured in accordance
with the data entered in the configuration menu.
NOTE: If the configuration group is abandoned without
the implementation of the operation described above,
introduced settings will not be saved in the calculator.
Default conguration
of the calculator
– Additional inputs 1-4 set as impulse inputs with an
impulse frequency of 1 l/imp (communication with
the sensor inactive).
– Annual logs: 24 with average, maximum and
minimum values.
– Monthly logs: 172 with average, maximum and
minimum values.
– Daily logs: 662 with average and maximum values.
– Hourly logs: 1236 with instantaneous values.
– Minute-based logs: 1777, 5 min period, with
instantaneous values.
– Billing logs: 160.
– Tariff logs: 668.
– Maximum flow exceeded error: inactive.
– No flow error parameters: 48h, 10°C, flow thresh-
old 0, active error.
– Delta T: 0.1°C.
– Protocol in both modules: M-Bus, 2400, even.
– Averaging period: 60 min
– Transmission speed for optical port: 9600 bps.
– Tariffs: inactive.
– Measurement of cold: inactive.
– Negative difference temperature error: active.
– The maximum number of archived records
displayed:
– tariff: 40,
– minute-based: 120,
– hourly: 48,
– daily: 62,
– monthly: 36,
– annual: 6,
– billing: 12.
– Time of saving to the daily, monthly, annual
archive: hour: 1, day: 1, month: 7.
– Time of saving to the billing archive: hour: 1,
day:15, monthly basis.
– Time of return to the main menu indication: 120 s.
– Display ranges for the main menu and statistical
group: full.
– Network no.: 1.
– Customer number: serial number.
The above configuration is applicable unless at the
time of ordering no other specification was provided.