EasyManua.ls Logo

Apera Instruments PH60-E User Manual

Apera Instruments PH60-E
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Compatible models for PH60-E replacement probe:
PH60, PH60F, PH60S, PC60
How to replace the probe?
Screw off the probe ring, unplug the probe, plug in the new
replacement probe (pay attention to the probe’s position), and
screw on the probe ring.
The liquid inside the probe cap is 3M KCL storage solution
(SKU: AI1107). It helps keep the spear pH sensor’s accuracy.
The sensor must be always stored in this storage
solution when not in use. If it gets contaminated, replace it
with new ones. (Using other brands’ storage solution could
cause potential damage to the probe)
Go to www.aperainst.de to watch some tutorial videos.
We warrant this electrode to be free from defects in material and workmanship and
agree to repair or replace free of charge, at option of APERA INSTRUMENTS (Europe)
GmbH any malfunctioned or damaged product attributable to responsibility of APERA
INSTRUMENTS (Europe) GmbH for a period of six-month. This warranty does not
apply to defects resulting from actions such as misuse (violation of the instructions in
this manual or operations in the manner not specified in this manual), improper
maintenance, or unauthorized repairs. Warranty period is the time limit to provide free
service for the products purchased by customers, not the service life of the probe.
APERA INSTRUMENTS (Europe) GmbH
Wilhelm-Muthmann-Straße 15
42329 Wuppertal, Germany
Tel. +49 202 51988998
info@aperainst.de
www.aperainst.de
Question and Answer IconNeed help?

Do you have a question about the Apera Instruments PH60-E and is the answer not in the manual?

Apera Instruments PH60-E Specifications

General IconGeneral
TypePortable pH Meter
Resolution0.01 pH
Accuracy±0.01 pH
DisplayLCD
mV Range±1999 mV
mV Resolution1 mV
Temperature Resolution0.1 °C
IP RatingIP67
Electrode TypeReplaceable pH electrode
CalibrationUp to 5-point calibration
Temperature CompensationAutomatic
Power Supply4 x AAA batteries
Temperature Accuracy±0.5 °C
Operating Temperature0 to 50 °C

Summary

pH Probe Replacement

Replacement Procedure

Unscrew the probe ring, unplug the old probe, and attach the new replacement probe securely, paying attention to its position.

Storage Solution

The pH sensor must be stored in 3M KCL storage solution to maintain accuracy and prevent contamination.

Warranty Terms

Related product manuals