EC60 Premium Conductivity Tester
(EC/TDS/Salinity/Temp.)
Instruction Manual
APERA INSTRUMENTS (Europe) GmbH
www.aperainst.de
V6.3

Other manuals for Apera EC60

Question and Answer IconNeed help?

Do you have a question about the Apera EC60 and is the answer not in the manual?

Apera EC60 Specifications

General IconGeneral
BrandApera
ModelEC60
CategoryMeasuring Instruments
LanguageEnglish

Summary

Battery Installation

Keypad Functions Overview

Press Duration Distinction

Differentiate button press durations for tester functions.

MEAS Key Operations

Controls power, backlight, and measurement mode.

MODE Key Operations

Switches between measurement parameters and selects settings.

CAL Key Operations

Initiates calibration, confirms readings, and unlocks values.

Complete Kit Contents

Conductivity Calibration Procedure

Mode Selection and Probe Preparation

Switch to conductivity mode and rinse probe.

Calibration Solution Preparation

Pour calibration solutions into bottles.

Initiate Calibration Mode

Long press CAL to enter calibration mode.

One-Point Calibration Execution

Dip probe, stir, wait for stable reading, confirm.

Two-Point Calibration Guidance

Use second buffer if first calibration is inaccurate.

Conductivity Measurement Process

Measurement Execution Steps

Rinse probe, dip, stir, wait for stable reading.

TDS and Salinity Conversion Explained

Conversion factors for TDS/Salinity from conductivity.

Calibration Standards and Points

Supported calibration standards and number of points.

Calibration Frequency and Solution Care

Factory calibration, recalibration needs, solution replacement.

Temperature Compensation Factor

Default and adjustable temp. compensation settings.

Self-Diagnosis and Error Handling

Er1 Error Cause and Fix

Wrong buffer or damaged electrode, check solutions/electrode.

Er2 Error Cause and Fix

CAL key pressed prematurely, wait for stable reading.

Parameter Configuration

Parameter Overview Table

Lists parameters P1-P7, their content, and defaults.

Navigating Parameter Settings

Procedure to enter, select, and confirm parameters.

Parameter Setting Instructions

Details on Auto Lock, Backlight, and Factory Default settings.

Technical Specifications

Icons and Functions Explained

Calibration Point Indicators

Icons (L, M, H) indicating calibration points.

Measurement Status Indicators

Icons for stable measurement, auto-lock, and low voltage.

Backlight and Auto Power Off

Two-color backlight modes and auto power off function.

Probe Replacement Guide

Compatible Probe Models

Lists compatible replacement probe model numbers.

Warranty Information