f. In the event of an emergency, pull up on the red emergency switch to unclamp the
door. When the water empties below the lowest sensor the door will come down.
g. In the event of a complete power failure to the facility or the unit. Hold down on the
small black bleeder button until all the air is released from the system, then the door
will be able to be pushed down by hand and the person can the be removed from the
tub.
7. TUB DOOR WILL NOT UNCLAMP WITH POWER TO THE TUB.
a. If the tub door will not come down and there is still power to the tub, kill all power to
the tub. Drain the water out of the tub. Using the air bleeder valve, hold down the
valve until all the air is bled from the system. Then the door can be pushed down by
hand. Call Apollo customer service for further assistance at 715-247-5625.