FOR REFRIGERANT RECOVERY
OPERATION MANUAL
COPYRIGHT © 2016 - APPION INC. - ALL RIGHTS RESERVED
APPION
TM
AND G5TWIN
TM
ARE TRADEMARKS OF APPION INC.
WARNING
TO REDUCE THE RISK OF INJURY OR PRODUCT
DAMAGE, READ OPERATION MANUAL PRIOR TO
OPERATING PRODUCT.
Explosion Hazard. Do NOT use with hydrocarbons. See page 4.
DANGER
www.AppionTools.com

Questions and Answers

Summary

Warnings and Safety Information

Operator Training and Safety Precautions

Emphasizes trained technicians, PPE, and general safety warnings for operating the machine.

Hazard: Explosion or Fire Risk

Details potential ignition risks from electrical sparks and flammable vapors, and prevention methods.

Breathing, Component, and Noise Hazards

Covers breathing hazards, moving parts dangers, unattended operation, and noise risks.

Refrigerant Storage Container Safety

Getting Started

Machine Usage

Standard Recovery Procedure

Details the step-by-step process for performing a standard refrigerant recovery using the G5Twin.

High-Speed Direct Liquid Procedure

Explains the method for fastest refrigerant recovery by pumping liquid directly.

Standard Recovery with Inline Cooling

Describes an alternative procedure for recovery, useful for managing temperatures and back-pressure.

Push;Pull Recovery Procedure

Details the push/pull method for recovering large amounts of liquid refrigerant via a siphon.

Care and Maintenance

Troubleshooting Guide

Machine Specifications

Summary

Warnings and Safety Information

Operator Training and Safety Precautions

Emphasizes trained technicians, PPE, and general safety warnings for operating the machine.

Hazard: Explosion or Fire Risk

Details potential ignition risks from electrical sparks and flammable vapors, and prevention methods.

Breathing, Component, and Noise Hazards

Covers breathing hazards, moving parts dangers, unattended operation, and noise risks.

Refrigerant Storage Container Safety

Getting Started

Machine Usage

Standard Recovery Procedure

Details the step-by-step process for performing a standard refrigerant recovery using the G5Twin.

High-Speed Direct Liquid Procedure

Explains the method for fastest refrigerant recovery by pumping liquid directly.

Standard Recovery with Inline Cooling

Describes an alternative procedure for recovery, useful for managing temperatures and back-pressure.

Push;Pull Recovery Procedure

Details the push/pull method for recovering large amounts of liquid refrigerant via a siphon.

Care and Maintenance

Troubleshooting Guide

Machine Specifications

Appion G5Twin Specifications

General IconGeneral
Vacuum Pump TypeDual Stage
Free Air Displacement5 CFM
Power SourceElectric
TypeVacuum Pump
ModelG5Twin
ManufacturerAppion
Voltage115V
Oil Capacity16 oz
Refrigerant CompatibilityAll refrigerants
Hose Connections1/4" SAE