FIGURE 7
FIGURE 8
FIGURE 10
FIGURE 9
10-11490
10-11491
10-11498
10-11491
2. The “L” bracket can removed to form a 10”x 24” drop opening. See Figure 6.
3. If the cold air drop is less than 24 inches deep an angle bracket can be field fabricated and installed to reduce the drop width.
See Figure 7.
4. The cold air return can be moved into position over the top of the air cleaner (Figure 8) or transition pieces field fabricated
(Figure 9).
5. Four tabs are located on the outlet side of the air cleaner. These tabs can be bent into the cold air return opening on the HVAC
equipment to hold the air cleaner in position during installation. See Figure 10.
FIGURE 6
10-11490
BEND ALL
TABS UP
FIELD FABRICA
TED
ANGLE BRACKET
COLD AIR
RETURN DROP
MOVED
FIELD
F
ABRICATED
TRANSITION
30° MAX
ANGLE
3