Model 1610 Easy Install
Media Air Cleaner
Installation Instructions
1. High voltage may cause serious
injury from electrical shock.
Disconnect power to the
furnace/air handler before
starting installation.
2. Sharp edges may cause injury
from cuts. Use care when cutting
and handling sheet metal.
WARNING
1. To prevent component failure, do not install the air cleaner on the warm
air supply or in an area where the temperature may exceed 140°F. This
may include areas above heat exchangers in downflow furnaces or above
exhaust flues in lowboy furnace cold air returns.
2. Installation must be done by a qualified heating and air conditioning
professional. Read instructions thoroughly before beginning installation.
3. Do not install air cleaner downstream of a UV light. UV lamps will cause
degradation of the filtering media.
CAUTION
SPECIFICATIONS
Airflow Capacity: up to 2000 CFM maximum
Replacement Media: Model 410 or 413 with SelfSeal
Air Cleaner Operating Environment: Temperature: 0°F – 140°F
DIMENSIONS
10-11479
FIGURE 1 – Air Cleaner Dimensions
Question and Answer IconNeed help?

Do you have a question about the Aprilaire 1610 and is the answer not in the manual?

Aprilaire 1610 Specifications

General IconGeneral
Product TypeAir Cleaner
Model Number1610
Filter Life6-12 months
Airflow Capacity2000 CFM
Voltage120V
Air FlowUp to 2000 CFM
MERV RatingMERV 11

Summary

Air Cleaner Specifications

Airflow Capacity

Specifies the maximum airflow the air cleaner can handle, up to 2000 CFM.

Replacement Media Compatibility

Identifies compatible replacement media models: Model 410 or 413 with SelfSeal™.

Operating Environment Temperature Range

Defines the acceptable operating temperature range for the air cleaner: 0°F – 140°F.

Air Cleaner Dimensions

Locating the Air Cleaner

Mounting Location and Door Reversibility

Details mounting options on HVAC equipment and door/blanking plate reversibility.

Filter Media Removal Clearance

Specifies the required 29" clearance for removal of the filtering media.

Easy Installation Features

Adjustable Cold Air Return Opening

Explains adjusting the cold air return opening between 8" and 10" by bending tabs.

L Bracket for Return Drop Alignment

Describes offsetting the 'L' bracket to match the return drop location.

Cold Air Return Drop Modifications

Creating 10"x 24" Drop Opening

Instructions for removing the 'L' bracket to form a 10"x 24" opening.

Field Fabricated Angle Bracket

Guidance on fabricating brackets to reduce cold air drop width.

Cold Air Return Duct Positioning

Methods for positioning the cold air return over the air cleaner.

Securing Cabinet with Mounting Tabs

Using bent tabs on the cabinet to secure it to the HVAC opening.

Install the Air Cleaner Cabinet

Disconnect Power and Prepare Unit

Essential safety step: disconnect power and remove filter media.

Cabinet Mounting and Ductwork

Steps for mounting the cabinet and connecting return ductwork.

Sealing Connections and Final Assembly

Instructions for sealing connections and installing the filter/door.

Reconnect Power

Final step to reconnect power to the furnace/air handler.