READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION
This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.
This product must be installed in compliance with all local, state and federal codes.
P
roper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices.
ATTENTION INSTALLER:
MODEL 400 SERIES HUMIDIFIER
The Model 400 and 400M Aprilaire can be
installed on either the supply or return
plenum of a forced air handling system and is
easily reversible for installation with right
hand or left hand bypass duct connections.
The humidifier dimensions and serviceability
must be considered when selecting the best
location for the humidifier. Here are
2 examples of many types of installations.
RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357
Horizontal
Upflow
90-1079
WARNING
1
.
ELECTRICAL SHOCK HAZARD.
Disconnect electrical power to the
furnace before starting installation.
Failure to do so could result in
serious injury from electrical shock.
2.
SHARP EDGES HAZARD. Sharp
edges may cause serious injury from
cuts. Use care when making plenum
openings and handling ductwork.
3.
RISK OF SCALDING. Water
temperature over 125°F can cause
severe burns and scald instantly.
Shut off the hot water supply before
disconnecting or tapping into any
h
ot water supply line.
SPECIFICATIONS
HUMIDIFIER DIMENSIONS
Width (including solenoid valve): 15
3
⁄8”
Height
(including drain spud): 15
3
⁄4”
Depth
: 10
1
⁄4”
BYPASS DUCT OPENING
6” diameter
PLENUM OPENING
10”W x 12
3
⁄4”H
ELECTRICAL DATA
24 VAC-60 Hz, 0.5 AMP
CAUTION
1. Do not install humidifier where freezing temperatures
could occur. The water line could freeze and crack
causing water damage to the home.
2. Do not install humidifier or bypass connection on the
furnace jacket.
3. Do not install humidifier or bypass connection on a
plenum face where the blanked off ends of the cooling
coil will restrict air movement through the humidifier.
4. Do not set humidity level above recommended or to
recommended level if condensation exists on inside
windows of any unheated space, as condensation
damage may result. Excess humidity can cause
moisture accumulation which can allow the possibility
for mold growth in the home.
5. Do not connect Model 400 or 400M
transformer to blower motor wiring. Premature
component failure may result.
6. When installing Humidifier Control on
downflow furnace, ensure blower continues to
run after a heat call is satisfied to eliminate
high temperatures from damaging the Control.
7. Do not install humidifier where water pressure
exceeds 125 psi, since damage to the
humidifier may result. Follow codes in effect
concerning pressure reduction.
8. Do not install humidifier on systems with
greater than 0.4 in. wg pressure differential
between supply and return plenums.
R
ISK OF PROPERTY AND EQUIPMENT DAMAGE.
INSTALLATION
OPTIONS
RECOMMENDED WIRING DIAGRAM
(SEE STEP 7 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS)