- 25 -
SWING APRICODE 230
CONTROL UNIT
English
parameters
FUNCTION .................................. DEFAULT SETTINGS
LO
Logic ...........................................
AUTOMATIC
0 = AUTOMATIC; 4 = STEP-BY-STEP; 1 = FOUR STEPS;
5 =
MANNED; 2 = SUPER AUTOMATIC; 6 = TIMER (START INPUT)
3 = SEMI AUTOMATIC WITH STOP;
PA Pause time..................................... 25 sec.
0 ÷ 60 (1 SECOND STEPS)
ELS.
Electric lock .............................................
DISABLED
IF CONNECTED ENABLED AUTOMATICALLY
FOLLOWING
SELF-TEACH PROCEDURE
0 =
DISABLED
1 = ENABLED
LAm.
Pre- ashing time
...............................3 sec.
1 ÷ 9 (1-SECOND STEPS)
tA.
Additional time at end of movement ..
6 sec.
3 ÷ 20 (1-SECOND STEPS) - ADDITIONAL THRUST IS AT REDUCED SPEED IF
ELECTRONIC SLOWING IS USED (rEl)
t1.
Additional time after reverse .............
6
sec.
3 ÷ 20 (1-SECOND STEPS)
nM
Number of wings ............... automatically
detected 0 = AUTOMATICALLY DETECTED ; 1 = SINGLE WING ; 2 = DOUBLE WING
d1. ; d2.
Direction wing 1 .....................................
0
Direction wing 2 .....................................
0
0 ; 1
Mod.
Operator type ................................
HYDRAULIC
0 = HYDRAULIC (NOT E1 - E2); 1 = ELECTRO-MECHANICAL
E1.
E2.
Power wing 1 .......................................MAX
Power wing 2 .......................................MAX
(ONLY ELECTRO-MECHANICAL OPERATORS)
THRUST FORCE ELECTRONIC ADJUSTMENT:
0 (MINIMUM) ÷ 50 (MAX)
rEL.
Electronic slowing............................
ENABLED
0 (DISABLED) ; 1 (ENABLED)
PSET.
Restore factory settings (default)
RED TO CONFIRM
man.
Access MAINTENANCE menu RED To CONFIRM
RadI
Access MEMORIES menu RED To CONFIRM
Prof
Access ADVANCED programming RED To CONFIRM
A1 Wing 1 closing delay ........................... 5
SDgr
0 ÷ 15 (1 STEP = 5° OF DISPLACEMENT)
A2 Wing 2 opening delay ......................... 2
SDgr
0 ÷ 5 (1 STEP = 2,5° OF DISPLACEMENT)
A3
Pedestrian opening ..........................
DISABLED
0= 20%; 1= 40%; 2= 60%; 3=80%; 4= 100%
A4
Electric lock actuation time
...................3.5 sec.
3 ÷ 6 (0.5-SECOND STEPS)
A5
Electric lock advance .........................0.5 sec.
0 ÷ 1 (0.5-SECOND STEPS)
A6
Reverse stroke time .........................
DISABLED
IF ELECTRIC LOCK CONNECTED .....................0.5 sec.
0 ÷ 2 (0.5-SECOND STEPS)
Reverse stroke: opening preceded by brief operation in the
reverse direction to facilitate release of the electric lock.
A7 Maximum torque time following startup ..1 sec.
0 ÷ 3 (0.5-SECOND STEPS) (only electro-mechanical)
A8
Reverse time at end of closing
...........0 sec.
0=0; 1=30; 2=50; 3=80; 4=100; 5=120; 6=150; 7=200; 8=300; 9=400 (MSEC.)
At the end of closing the motors are operated in reverse direction for the
time set to discharge the mechanisms when movement is complete.
A9 Approach speed ................................... 30%
1= 30% ; 2= 40% (% OF MOVEMENT SPEED)
rat
Factory setting - Do NOT modify 0 ÷ 2 - DO NOT MODIFY
LUM
Display luminosity ..............................
MEDIUM
0 ÷ 9
Ad
Closing when photocell
uncovered .............................. reloads pause time
00= IMMEDIATELY ; 01= AT THE END OF PAUSE TIME
(COUNTING CONTINUES
)
; 02= AFTER
10SEC
. ; 03= AFTER A NEW COMPLETE PAUSE TIME
(RELOADS
THE PAUSE TIME
)
Ae
Auxiliary output ...........................
WARNING LIGHT
0 = WARNING LIGHT; 1÷60 = MINUTES COURTESY LIGHT ON AFTER
START OR PEDESTRIAN START
NOTE
: only if not set on remote control
AH
Flashing light during pause ...................
OFF
0= OFF; 1= ON (IN AUTOMATIC MODE)
AM
100% nal thrust time.....................
DISABLED
If electric lock connected ...................1 sec.
0 ÷ 5 (
DURING CLOSING FOR ELECTRIC LOCK ENGAGE)
Ar.
Aux. opening safety device .......
with PHOTOCELL
0= SAFETY EDGE; 1= PHOTOCELL
tf.
Closing photocell test .....................
DISABLED
0 = DISABLED; 1 = STANDARD PHOTOCELL TEST ; 2 = REFLEX PHOTOCELL TEST
An.
Aux. opening safety device test ....
DISABLED
0 = DISABLED; 1 = STANDARD PHOTOCELL OR EDGE TEST;
2 = REFLEX PHOTOCELL OR EDGE TEST
AL.t
Movement Total counter (cannot be modi ed)
0000 ÷ 9999 (INCREASES BY 1 FOR EVERY 100 MOVEMENTS)
AL.P
Movement Partial counter for maintenance
0000 ÷ 9999 (1 = 10 MOVEMENTS) (RESET USING AL.S OR AL.r)
AL.S
Sets maintenance cycle on AL.P
0000 ÷ 9999 (1 = 10 MOVEMENTS) WITH MINIMUM STEP 100 MOVEMENTS
- EACH SETTING ZERO-SETS THE COUNTER AL.P
aL
.r
Zero-sets the counter AL.P
RED TO CONFIRM
Open
Saving the remote controls on the
built-in receiver Apricode ...........open the memory
RED TO CONFIRM (THE DISPLAY SHOWS seed FOR15 SEC.)
rn.
Deleting a remote control with address 0 ÷ 99 (see Programming remote controls)
r.tr
Deleting all remote controls RED TO CONFIRM
UPLd
Saving control unit data on Plug-in memory module
RED TO CONFIRM - (OPTIONAL PLUG-IN MEMORY MODULE
)
dnLd
Saving data from Plug-in memory module on control unit
RED TO CONFIRM - (OPTIONAL PLUG-IN MEMORY MODULE
)
ch1
ch2
ch3
ch4
Remote control Output channel setting
ch1 .................................................
START
ch2 ..................................... PEDESTRIAN
START
ch3;ch4......................................... DISABLED
0 = DISABLED; 1 = START; 2 = PEDESTRIAN START; 3 = STOP;
4 = AUXILIARY OUTPUT USING EXTERNAL RELAIS (2 sec. pulse if Ae= 0;
timer 1÷60 if
Ae= 1÷60)