  • G
    george14Aug 9, 2025
    What to do if the APT Inverex XP Pro 1200 buzzer beeps continuously and the red LED is on?
    • T
      Traci HarperAug 9, 2025
      If the buzzer beeps continuously and the red LED is on, it could be due to several reasons: * A short circuit in the output: Check the wiring and remove any abnormal load. * An overload error: Reduce the connected load by turning off some equipment. * Output voltage is too high or too low: Return the unit to a repair center. * Fan fault: Replace the fan.
  • R
    Ryan RamseyAug 19, 2025
    Why does my APT Inverter work in battery mode when mains exist?
    • B
      blakekhanAug 20, 2025
      The APT Inverter might be working in battery mode even when mains are available due to: * A tripped input protector: Check if the AC breaker is tripped and ensure the AC wiring is properly connected. * Insufficient AC power quality: Inspect the AC wires for being too thin or long. Also, if using a generator, verify it's functioning correctly and that the input voltage range setting (Narrow/Wide) is appropriate.
  • S
    Steven BakerAug 28, 2025
    What to do if there is no LED display on the APT Inverter when the utility power is normal?
    • D
      Dr. Allen Smith DVMAug 28, 2025
      If there is no LED display on the front panel when the utility power is normal, the possible causes are: * Poor battery connection: Check the external battery cable and terminal to ensure all battery connections to the unit are correct. * Defective battery: Replace the batteries.

Summary

Important Safety Warning

General Precaution

Unit is for indoor use only. Do not expose to liquids. Use qualified batteries and appropriate cables.

Personnel Precaution

Precautions for working with batteries: avoid metal objects, sparks, flames, and ensure safety.

Product Overview

Mounting the unit

Instructions on how to mount the unit vertically to a wall surface.

Connect to Utility and Charge

Connect the AC input cord to charge the external battery, even when the unit is off.

Connect External Battery

Step-by-step guide for connecting external batteries, including polarity and cable requirements.

Installation

LCD Setting

Setting Programs

Details on setting programs for AC input voltage range, battery type, charging current, and voltages.

Trouble Shooting

Specifications

APT Inverex XP Pro 1200 Specifications

General IconGeneral
ModelXP Pro 1200
CategoryInverter
Capacity1200 VA / 720 W
WaveformPure Sine Wave
Operating Temperature0°C to 40°C
Dimensions320 x 130 x 182 mm
Battery TypeLead Acid
Frequency50 Hz
Battery Recharge Time4-6 hours
ProtectionOverload, Short Circuit
Input Voltage220-240V AC