SERVICE MANUAL
SECOND STAGE
LX and LEGEND
Copyright ©2005 Aqualung France
Rev. 02/2005

Questions and Answers

  • J
    Jeremy KingJul 31, 2025
    What to do if there is a leak or free flow at the 2nd stage of my Aqua Lung LX Supreme?
    • R
      Robert MartinezJul 31, 2025
      If you experience a leak or free flow at the 2nd stage of your Aqua Lung Diving Instrument, several factors could be responsible. The intermediate pressure (MP) might be too high or too low, in which case you should refer to the First Stage Troubleshooting Guide. Alternatively, the valve could be worn or damaged, requiring replacement. The seat might not be correctly adjusted, so readjusting the seat may solve the issue. Other potential causes include a bent lever (replace the lever), a damaged seat sealing face (replace the seat), or a damaged spring (replace the spring). Finally, the valve might not be correctly adjusted, or the lever adjustment might be too low; in this case, readjust the lever and the valve.
  • M
    milesalexAug 13, 2025
    Why is my Aqua Lung Diving Instrument leaking water?
    • G
      Gail WilliamsAug 13, 2025
      If your Aqua Lung Diving Instrument is leaking water, there are several possible causes. A hole in the mouthpiece could be the culprit, requiring you to replace the mouthpiece. Alternatively, the diaphragm or the exhalation valve might be damaged, necessitating their replacement. A dirty, worn, or damaged venturi control O-ring could also be the cause, so replacing the O-ring might resolve the issue. Check that the diaphragm is correctly fitted between the casing and the washer. If not, disassemble the purge button and refit the assembly correctly. Inspect the sealing face of the exhalation valve for damage to the casing; if damaged, replace the casing. Finally, a damaged O-ring or insert O-ring could be the cause, requiring you to replace the O-ring.

Summary

Warnings, Attention, Notes

Maintenance

General Instructions

General Conventions

Defines actions for instructions like unscrewing and screwing.

Disassembly Procedure

Note on Parts Replacement

Consult exploded view, replace all parts, use special tools for O-rings.

O-ring Removal Caution

Use special tool to avoid damaging seal recess and causing leaks.

Re-assembly Procedure

Preparation for Re-assembly

Ensure parts are cleaned and lubricated per Procedure A.

Final Checks

Test Bench Usage Note

Tests require a Regulator Test bench for accurate results.

Procedure A Cleaning and Lubricating

Cleaning Metal Parts

Steps for cleaning brass, stainless steel, and Nitrox/O2 parts.

Cleaning Plastic and Hose Parts

Methods for plastic, rubber, anodised aluminium parts, and hoses.

Inspection and Lubrication

Visual inspection of parts and lubrication of seals.

Aqua Lung LX Supreme Specifications

General IconGeneral
TypeRegulator
Cold Water SuitableYes
Second Stage TypeBalanced Diaphragm
Nitrox CompatibilityYes
Environmental SealingYes
Intermediate Pressure9.5 bar