SERVICE MANUAL
SECOND STAGE
LEGEND LX
LEGEND LX
SUPREME
Copyright ©2005 Aqualung France
Rev. 02/2005

Questions and Answers

  • J
    James TorresAug 1, 2025
    What to do if there is a leak or free flow at the 2nd stage of my Aqua Lung Diving Instrument?
    • T
      Tiffany SmithAug 1, 2025
      If you're experiencing a leak or free flow at the 2nd stage of your Aqua Lung Diving Instrument, it could be due to several reasons. The MP might be too high or too low, in which case you should refer to the First Stage Troubleshooting Guide. Alternatively, the valve is worn or damaged, the seat is not correctly adjusted, the lever is bent, the sealing face of the seat is damaged, the spring is damaged, or the valve is not correctly adjusted. Replace the valve, readjust the seat, replace the lever, replace the seat, replace the spring, or readjust the lever and the valve, depending on the cause.
  • T
    Tammy LeachAug 11, 2025
    What to do if my Aqua Lung Diving Instrument has a water leak?
    • S
      Stephen ThompsonAug 11, 2025
      If you notice a water leak in your Aqua Lung Diving Instrument, several issues could be the cause. It might be due to a hole in the mouthpiece, a damaged diaphragm, or a damaged exhalation valve. The venturi control O-ring could be dirty, worn, or damaged. The diaphragm might not be correctly fitted between the casing and the washer, the casing could be damaged or the O-ring or insert O-ring could be damaged. Replace the mouthpiece, replace the diaphragm, replace the valve, replace the O-ring. Disassemble the purge button and refit the assembly correctly. Check the sealing face of the exhalation valve and replace the casing. Replace the O-ring.
  • J
    Jason BrownAug 20, 2025
    Why is the purge flow insufficient or work of breathing too high on my Aqua Lung Diving Instrument?
    • R
      Roberta DeleonAug 20, 2025
      If you're experiencing insufficient purge flow or the work of breathing feels too high with your Aqua Lung Diving Instrument, it could be due to a couple of reasons: either the MP hose is obstructed, or the lever is bent. Try cleaning or replacing the hose, or replacing the lever.

Summary

General Information

General Instructions

Core instructions for servicing the regulator.

General Conventions

Definitions of actions and symbols used in the manual.

Maintenance

Service interval and record keeping for the regulator.

Disassembly Procedure

Re-assembly Procedure

Final Checks

Procedure A. Cleaning and Lubricating

Exploded Views

Exploded view of Legend LX second stage

Visual parts breakdown with references for Legend LX.

Exploded view of Legend LX Supreme second stage

Visual parts breakdown with references for Legend LX Supreme.

Aqua Lung SECOND STAGE Specifications

General IconGeneral
BrandAqua Lung
ModelSECOND STAGE
CategoryDiving Instrument
LanguageEnglish