COMMISSIONING THE SHOWER
1. Make sure that the electrical supply has been isolated at the double pole isolating switch.
2. Turn the divertor handle to the left position (Button at 9 O’clock for hand-shower function)
(Button at 3 O’Clock for Overhead position).
3. Turn the volume handle fully anticlockwise to the maximum volume position.
4. Ensure that the water supply is fully on at the mains stop cock and isolating service valve.
5. Switch on the electrical supply at the double pole switch.
The Aquas digital heater has 3 settings and automatically defaults to the COLD ONLY setting.
6. Press the On / Off Button. This action will activate the internal solenoid valve
and start the water flowing at maximum volume.
7. Press the Middle Digital button with the MINUS Symbol …Once Lit , .this will activate the heater
to deliver warm water up to a max heating capacity of 5.0 KW power (Summer Setting)
8. Press the Higher Digital button with 2 MINUS Symbols …Once Lit , .this will activate the heater to
deliver maximum hot water with a maximum heating capacity of 9.5 KW power (Winter Setting)
9. Rotate the volume handle at setting step. NOTE …as you lower the flow rate ,
the warmer the outlet temperature of the water will become.
10. Push the On / Off button to stop the water flow from the heater …
The Aquas heater is preset to a COLD START MODE….see below important note.
11. Switch off pull cord or wall mounted switch.
12. Remove the hand-shower and overhead to make sure they are not blocked with debris from
the water. If necessary clean and refit.
13. Remove the filter and clean out any debris from the residual pipework.
Clean and refit - For the Filter Removal see section on maintenance.
IMPORTANT NOTE
If the outlet temperature is lower than 55 degree: after turning off the shower heater,
water will still flow out for 6 seconds to reduce residual heat in the water tank,
designed as a safety feature to protect the next user.