Software rel. 2.3.x
RPM INDICATOR + SURFACE VERSION

Other manuals for ARAG Visio

Questions and Answers

  • J
    joshuarussellAug 20, 2025
    How to fix ARAG Measuring Instruments VISIO if it is off or does not switch on?
    • J
      Jason SloanAug 20, 2025
      If your ARAG Measuring Instruments VISIO is off or not turning on, check the power cable connections to ensure a proper power supply. If the power supply is fine, make sure the device is turned ON by pressing the ON key.
  • T
    Todd SolisAug 22, 2025
    What to do if my ARAG Measuring Instruments VISIO shows wrong data?
    • T
      tommyjohnsonAug 22, 2025
      If your ARAG Measuring Instruments VISIO displays incorrect data, there might be a setup issue. Verify the displayed data setup. Alternatively, there could be a sensor fault; in this case, contact the nearest Assistance Center. A VISIO fault may also cause this issue.
  • D
    Douglas CookAug 25, 2025
    What to do if my ARAG Monitor VISIO is off or does not switch on?
    • K
      Kevin SullivanAug 25, 2025
      If the ARAG Monitor VISIO is off or doesn't switch on, there are a couple of things to check: * First, ensure that the device has power by checking the power supply connection. * Second, verify that the device is turned on by pressing the ON key.
  • S
    Stephanie RossAug 27, 2025
    Why does my ARAG Monitor VISIO show wrong data?
    • M
      Mark MooreAug 27, 2025
      If your ARAG Monitor VISIO shows wrong data, it could be due to a few reasons. First, verify the displayed data setup to ensure it is correct. Another potential reason is a sensor fault.
  • J
    Justin WongAug 28, 2025
    How to troubleshoot filling pump not starting on my ARAG Monitor?
    • D
      Dr. Sean Rojas MDAug 28, 2025
      If the filling pump on your ARAG Monitor does not start, the pump stop module may not be powered. Check the power supply connection to resolve this.
  • M
    Michael GordonAug 30, 2025
    What to do if ARAG Data Loggers displays 'Check sensor!'?
    • K
      Karen HoffmanAug 30, 2025
      If the ARAG Data Loggers displays 'Check sensor!', it means recording is immediately interrupted because the sensor is either not properly connected or is damaged. Check the connections of the sensor corresponding to the alarm and the connection cable status. Also, verify the sensor's operation in Setup menu > Diagnostics > Sensors: the values must be between 3.5 mA and 20.5 mA for each sensor connected.
  • R
    Robert CordovaSep 1, 2025
    What to do if ARAG Data Loggers displays 'Too high pressure!'?
    • B
      Beverly BaileySep 1, 2025
      If the ARAG Data Loggers displays 'Too high pressure!', it indicates that the measured pressure exceeds the maximum value set in Setup menu > Alarms. Reduce the pressure to a correct value.
  • T
    Tina CarterSep 2, 2025
    What to do if ARAG Data Loggers displays 'Too low pressure!'?
    • M
      Mark OdonnellSep 3, 2025
      If the ARAG Data Loggers displays 'Too low pressure!', it means that the measured pressure is lower than the minimum value set in Setup menu > Alarms. Increase the pressure to a correct value.
  • D
    Daniel MurraySep 4, 2025
    Why ARAG Data Loggers display shows a wrong pressure value?
    • T
      Tiffany HendersonSep 4, 2025
      If the ARAG Data Loggers display shows a wrong pressure value, it may be due to a programming error where the connected pressure sensor doesn't match the programmed one. Correctly program the sensors in the proper menu (par. 11.1).
  • A
    Amy TuckerSep 6, 2025
    What to do if ARAG Data Loggers display does not switch on?
    • K
      Kathryn TurnerSep 6, 2025
      If the ARAG Data Loggers display does not switch on, it is likely due to no power supply. Check the power supply connection.

Summary

General Safety Precautions

Assembly Risks and Safety

Mounting and Positioning Guidelines

Guidance on optimal placement of the VISIO unit in the cabin.

Power and Sensor Connection Procedures

Instructions for correctly connecting power supply and sensors to the device.

Device Operation and Menu Access

Preliminary Setup Procedures

Configuring Speed Alarms

Setting minimum and maximum speed thresholds for alarm notifications.

Speed Sensor Calibration Process

Automatic Speed Sensor Calibration

Manual Speed Sensor Calibration

Units of Measurement Configuration

Surface and Distance Unit Configuration

Display Contrast Settings

Display Data Configuration

Boom Length Setup

Operating Mode Configuration

USB Setup Management

Loading Setup Files

Procedure to load a configuration file from a USB drive.

Saving Setup Files

Device Testing Procedures

Sensors Test Procedure

VISIO Device Usage

Maintenance and Troubleshooting Guide

Troubleshooting Common Faults

Lists common faults, their causes, and recommended remedies.

Technical Specifications Overview

Detailed Device Specifications

Provides detailed technical specifications for the VISIO device.

ARAG Visio Specifications

General IconGeneral
Refresh Rate60 Hz
Response Time5 ms
Brightness250 cd/m²
Contrast Ratio1000:1
VESA Mount100 x 100 mm
DisplayLED
InputsVGA