  • K
    Keith WhitneySep 12, 2025
    What does “Err2” mean on my ARB 78L's display?
    • L
      Laura MillerSep 12, 2025
      If your ARB Refrigerator's digital display shows “Err2”, the thermistor circuit is ‘short circuit”. Test the thermistor and replace it if necessary.
  • S
    Stephanie McdonaldSep 12, 2025
    What does “Err1” mean on my ARB 78L's display?
    • R
      Richard McknightSep 12, 2025
      If your ARB Refrigerator's digital display shows “Err1”, the thermistor is not correctly connected to the control panel circuit board; check its connection. Alternatively, the thermistor circuit may be ‘open circuit’; test the thermistor and replace it if necessary.
  • N
    Nicole ScottSep 10, 2025
    Why does the lid of my ARB 78L Refrigerator open while driving?
    • A
      Amy SpencerSep 10, 2025
      If your ARB Refrigerator's lid opens during transit, first, ensure that the latch was correctly closed before transportation. If the issue persists, inspect the latch and latch pivot for damage, and replace the latch assembly if necessary, as the latch may be faulty.
  • M
    Michelle BakerSep 9, 2025
    Why is the latch on my ARB Refrigerator hard to disengage?
    • B
      Bryan TrevinoSep 9, 2025
      If the latch on your ARB Refrigerator does not easily disengage from the lid, it could be due to the high-quality seal causing the lid to sit away from the fridge cabinet; press down slightly on the lid to help disengage the latch. Alternatively, the latch itself may be faulty; inspect the latch and latch pivot for damage, and replace the latch assembly if necessary.
  • J
    Joshua FieldsSep 8, 2025
    Why is my ARB 78L not reaching the set temperature?
    • S
      Shannon JosephSep 8, 2025
      If your ARB Refrigerator does not reach the target temperature, it might be operating at its maximum cooling capacity in extreme ambient temperatures. The maximum cooling capability of the system is a reduction of 50°C (122°F) below the ambient temperature.
  • W
    William BuckAug 23, 2025
    What to do if my ARB 78L runs but does not cool?
    • E
      edwardsheltonAug 23, 2025
      If your ARB Refrigerator does not cool but the compressor runs, ensure there is sufficient clearance around the fridge and that the fan is not obstructed to provide proper ventilation. Check that the correct battery protection setting is selected. Inspect the lid seal for damage or if it's missing, and replace it if necessary. Also, look for any visible oil leaks around the refrigeration lines, compressor, and condenser. If you detect a leak or suspect a blockage within the refrigeration system, contact a qualified refrigeration mechanic for assistance.
  • N
    Natalie GraySep 6, 2025
    Why does my ARB 78L have an intermittent power supply?
    • R
      Robert DuncanSep 6, 2025
      If you are experiencing intermittent power supply to your ARB Refrigerator, it could be due to a poor connection of the plug into the socket at the back of the fridge, or a poor connection of the plug into the supply socket. Check that both plugs are correctly installed. It's also possible that the compressor has stopped running because the battery cut-out voltage has been reached. Ensure the correct battery protection setting is selected and that the vehicle wiring is adequate.
  • C
    Christopher AndersonSep 5, 2025
    Why won't my ARB 78L run when the voltage is above 13.8V?
    • B
      brownmichaelSep 5, 2025
      If your ARB Refrigerator will not run when the DC input voltage exceeds 13.8V, the main circuit board may be faulty. Replace the main circuit board and retest to resolve the issue.
  • J
    Jeremy BookerSep 4, 2025
    What does it mean when the error light flashes twice on my ARB Refrigerator?
    • Z
      Zachary WagnerSep 4, 2025
      If your ARB Refrigerator does not run, and the error light flashes twice every 5 seconds, it could be due to a few reasons. The fan might not be correctly connected to the compressor control unit, so check the fan wiring to ensure the "+ve" and "–ve" fan wires are properly connected. Alternatively, the fan itself could be faulty, in which case you should test and replace it if necessary. Lastly, the compressor control unit might be faulty, requiring testing and potential replacement.
  • K
    Kayla StrongSep 3, 2025
    Why does the device fuse in my ARB 78L Refrigerator keep blowing?
    • M
      Ms. Kimberly BrownSep 3, 2025
      If your ARB Refrigerator's device fuse repeatedly blows, it could be due to a short circuit in the 100-240V AC fridge cable. Check the cable's continuity and replace it if it's faulty or damaged. Another cause could be a short circuit between the "L" and "N" terminals on the compressor control unit; check for this. Lastly, an unregulated or fluctuating power supply, such as from an engine-driven generator, might be the issue. Ensure the generator has a voltage regulator and supplies a standard, pure sine wave AC voltage without fluctuations.

Summary

Warranty Information

ARB Fridge Freezer Limited Warranty

Details warranty coverage, exclusions, and terms for ARB fridge freezers.

Warranty Procedure for Service Agents

Step-by-step process for service agents to submit and process warranty claims.

Standard Service and Warranty Times

Spare Parts Information

Spare Parts List

Comprehensive list of all available spare parts with corresponding part numbers.

Troubleshooting Guide

Check Diagnosis Lights

Explains fridge error codes indicated by flashing diagnostic lights.

DC Power Supply Issues

Troubleshoots issues related to 12/24V DC power input and operation.

AC Power Supply Issues

Troubleshoots problems associated with 100-240V AC power supply.

Cooling Performance Issues

Diagnoses and resolves issues related to the fridge's cooling performance.

Battery Protection Settings

Explains battery monitor modes and voltage cut-off levels for DC operation.

Fault Finding Flow Charts

Fridge Not Running on AC Power

Visual guide to diagnose why the fridge won't operate on AC power.

Fridge Not Running on DC Power

Visual guide to diagnose why the fridge won't operate on DC power.

Checks and Tests Procedures

Test Compressor Control Unit (12;24 V DC)

Verifies the correct operation of the compressor control unit on DC power.

Test Main Circuit Board (100-240 V AC)

Tests the AC power section of the main circuit board for functionality.

Test Compressor Control Unit (100-240 V AC)

Verifies the correct operation of the compressor control unit on AC power.

Test Compressor

Checks the internal windings of the compressor for proper function.

Test Thermistor

Evaluates the thermistor's resistance value to ensure accurate temperature readings.

Service Procedures

Service by Refrigeration Mechanic

Leaks in the Refrigerant System

Procedures for pressure testing and locating refrigerant leaks.

Wiring Diagrams and Schematics

ARB 78L Specifications

General IconGeneral
BrandARB
Model78L
CategoryRefrigerator
LanguageEnglish

Related product manuals