8. Electronic function
8.1 Function
8.1.1 Cooling , Heating or Dehumidifying mode
8.1.2 Auto switch on, off and sleep mode function
8.1.3 Ts rangeCooling1730°CHeating1530°C (dados XL)
8.1.4 Time delay safety control
8.1.5 Auto Memory Function
8.2 Controller Specifications
8.2.1 Normal power source: 220VAC±15
8.2.2 Operation temperature for electrical system:
- working temperature range:-10°C~60°C
- storage temperature range:-20°C~70°C
- relative humidity range35~98%
8.2.3 Temperature sensorR25/50=5KB=3470 temperature precision±1°C
8.3 Controller Structure
The control logic consists of remote control, indoor control panel, indoor main control panel. The output of main
control is including motor fan ( high, mid, low fan speed), compressor.
8.4 Sensor Definitions
TA: Temperature of ambient, (T1).
TE: Temperature of evaporator, (T2).
TS: Setting temperature, (T3).