8.5 Mode
8.5.1 Cooling
8.5.1.1 In cooling mode, set point temperature is 17~30°C;starting temperature is 25°C.
8.5.1.2 Cooling mode - compressor working condition:
A: Under the condition of T1 - T3 ≥ +1°C, compressor will be running
B: Under the condition of T1 – T3 ≤ +1°C, the unit will be switched off, compressor will be off too
Each time the compressor and internal motor system will be switching back to the original setting
Note: When compressor is off, cooling operation light is flashing. When the compressor is running, the operation
light will be turned on.
8.5.2 Dehumidification mode
8.5.2.1 During dehumidification mode fan system is in “low” setting and the compressor is working.
8.5.2.2 Dehumidification mode.
A. If indoor temperature ≤0°C, compressor will be off.
B. If 0°C<indoor temperature≤20°C,compressor will be on for 15 min and stop for 3 min.
C.If indoor temperature>20°Ccompressor will be on for 30 min and stop for 3 min.
Note: When compressor stops, the dehumidification indication light is on.
8.5.3 Heating mode (dados XL)
8.5.3.1 Heating mode: set point temperature range is 15~30°C,starting temperature is 20°C.
8.5.3.2 Heating mode, compressor working condition
A. Under the condition of T3 - T1≥+1°C(2°F)compressor will be turned on
B. Under the condition of T3 - T1≤ + 1°C(2°F)compressor will be turned off
Each time the compressor and internal motor system will be switching back to the original setting
Note: When compressor is off, cooling operation light is flashing. When the compressor is running, the operation
light will be turned on.
8.6 Protection function
8.6.1 Compressor delay protection
8.6.1.1 When the unit is switched on, the compressor needs 3 min and 30 s in order to start to operate.