5.2.3. Cleaning of the Air Valve
Thoroughly wash and clean the air valve components under clean running water to remove all grime; Pay special
attention to the internal parts.
Thoroughly clean the O-ring (replace it if needed
[1]. Make sure that the O-ring is correctly seated
in its designated groove [2].
5.2.4. Assembly and Testing for Leaks
Reassemble the air valve in reverse order of paragraphs 5.2.3 and 5.2.2.
Slowly open the isolating valve located on the riser under the air valve.
Look for leaks in the Outlet Discharge Elbow.
If the air valve still leaks, proceed to Second Stage Maintenance