IOM D-040
5.3. Second Stage Maintenance
Perform if the first stage doesn't solve the leak, if one of
the seals or inner parts need replacement or for periodic
maintenance to thoroughly clean the valve.
5.3.1. Releasing Pressure
Shut the isolating valve located on the riser under the air valve
Carefully release the pressure and drain the air valve
Important: Discard liquid to comply with local regulations
5.3.2. Removal of the Air Valve Body
Slowly turn the Body (1) counterclockwise, and
remove it [2]
Remove the Discharge Outlet Elbow [3], [4] (snap-on
or thread)