FOR MODELS: JGI, JGM, JGN, JGP AND JGQ SECTION 4 LUBRICATION
9/08 PAGE 4-33
Lubriquip A-3533 5500 (379) A-3538 Orange
1/4 x 0.065
wall
(6.4 x 1.7)
10,200 (703) PT0201CD
Lubriquip A-3534 6400 (441) A-3539
Pink
d
Lubriquip A-3535 7300 (503) A-3540 Blue
a. Be sure to apply the proper rupture disk to match your blow-out fitting type, see Figure 4-11, and
application pressure. Generally the rupture disk should be rated about 1000 psig (70 bar
g
)
greater than the highest MAWP cylinder.
b. See Technical Manual Section 1, Fastener Tightening Values Table or the toolbox torque tables
(ER-63) for blow-out fitting cap tightening torque. Do not over tighten cap or rupture pressure
can be reduced.
c. All tubing down stream from a force feed pump for a pump circuit rated 5500 psig (380 bar
g
) or
greater (orange, pink and blue disks), that is circuits with any cylinders greater than 3600 psig
MAWP (248 bar
g
), should be 1/4 inch x 0.065 (6.4 x1.7 mm) heavy wall stainless steel high pres-
sure tubing. Rated tubing pressures are calculated from equations in ASME/ANSI B31.3 code
for pressure piping, based on maximum outside diameter and minimum wall thickness. When
grade 316 stainless steel tubing is specified on new compressor sales orders, 1/4 inch x 0.065
(6.4 x 1.7 mm) tubing is provided, regardless of rupture disk or cylinder ratings.
d. Color code changed to pink (3/20/05) was uncoated aluminum.
TABLE 4-12 BLOW-OUT FITTINGS, REPLACEMENT RUPTURE DISKS & TUBING
BLOW-OUT
FITTING
A
REPLACEMENT RUPTURE DISK
B
STANDARD TUBING - 304 SS
C
TYPE
ARIEL
P/N
RATING
psig (bar
g
)
ARIEL P/N COLOR
SIZE
in. (mm)
RATING
psig (bar
g
)
ARIEL
P/N