General Safety Instructions

General Safety Guidelines

Read instructions carefully for safe installation, use, and maintenance. Manufacturer not liable for improper use.

Electrical Safety Precautions

Avoid touching the appliance when barefoot or with wet body parts.

Specific Safety Precautions

Burn Risk Awareness

Water over 50°C can cause serious burns; recommend thermostatic mixer valve.

Legionella Function and Technical Specs

Installation Norms and Hydraulic Connection

Inlet Pipe Fittings and Safety Valve

Connect a 'T' piece union with a drain tap and the supplied safety valve.

Electrical Connection and Startup

Safety Group and Drainage Requirements

Connect drain outlet to a pipe with at least 20mm air gap; use pressure reducer if needed.

Electrical System Compatibility Check

Verify electrical system adequacy for maximum power absorption and local regulations.

Power Cable and Clamp Usage

Use specified cable type (H05VV-F 3x1.5mm²) and secure with provided clamps.

Grounding and Wiring

Ensure proper grounding with a yellow/green cable connected to marked terminals.

Initial Heater Filling Procedure

Fill the heater with mains water, opening hot water tap to vent air.

Maintenance Procedures

Safety Precautions Before Maintenance

Disconnect the appliance from the mains before conducting any maintenance work.

Appliance Draining Procedure

Empty the appliance by disconnecting mains, closing valves, opening hot tap, and opening drain valve.

Heating Element Replacement

Disconnect cable, undo screw, remove damaged element, and replace.

Periodical Maintenance and User Guidance

Hot Water Burn Hazard

Hot water over 50°C can cause severe burns; children, disabled, elderly at higher risk.

User Interface and Operating Modes

Operating Modes (Figure 8 Interface)

Cycles through Manual, Program 1, Program 2, and combined modes via the MODE key.

Operating Modes (Figure 9 Interface)

Cycles through Program 1, Manual, and Night modes via the MODE key.

Advanced Functions

Wi-Fi Heating Mode

Enable remote control and programming via the Aqua Ariston NET app.

ECO EVO Function

Learns user consumption for energy savings, optimizes heating, and minimizes heat loss.

Special Functions and Protection

PROTECH Function

Protects the tank against corrosion for excellent longevity, especially with aggressive water.

Thermal Disinfection Function (Anti-Legionella)

Heats water to 60°C for one hour to eliminate bacteria, activated by default.

Reset and Diagnostics

Error Code Reference List

List of error codes (E01-E70) indicating operational problems and their causes.

Appliance Reset Procedure

Reset the appliance by switching it off and on to resolve immediate malfunctions.

LED Fault Indicator Mapping

LEDs indicate specific faults like internal malfunction, probe errors, or overheating.

Wi-Fi Functionality and App Integration

Useful Information and Troubleshooting

Repair Caution and Technician Contact

Never attempt self-repair; always contact a qualified technician for persistent problems.