Training manual ALTEAS & GENUS ONE
Page. 88 of 88 Version 2V2.
Model: GENUS PREMIUM EVO SYSTEM
18
24
30
35
CE Certification (pin)
0085CL0440
Boiler type
C13(X)-C23-C33(X)-C43(X)-C53(X)-
C63(X)C83(X)-C93(X) B23-B23P-B33
Max/min nominal calorific flow rate (Pci)
kW
18,0/4,5
22,0/2,5
28,0/3,0
31,0/3,5
Max/min nominal calorific flow rate (Pcs)
kW
20,0/5,0
24,4/2,8
31,1/3,3
34,4/3,9
Domestic hot water max/min nominal calorific flow rate (Pci)
kW
18,0/4,5
26,0/2,5
30,0/3,0
34,5/3,5
Domestic hot water max/min nominal calorific flow rate (Pcs)
kW
20,0/5,0
28,9/2,8
33,3/3,3
38,3/3,9
Max/min power output (80°C-60°C)
kW
17,6/4,4
21,5/2,4
27,4/2,9
30,3/3,4
Max/min power output (50°C-30°C)
kW
19,1/4,7
23,4/2,6
29,7/3,1
33,0/3,6
Domestic hot water max/min power output
kW
17,6/4,4
25,4/2,4
29,3/2,9
33,7/3,4
Combustion efficiency (of flue gas)
%
98
98
98
97,9
Nominal calorific flow rate efficiency (60/80°C) Hi/Hs
%
97,6/87,9
97,8/88
97,7/88
97,7/88
Nominal calorific flow rate efficiency (30/50°C) (condensation) Hi/Hs
%
106,1/95,5
106,2/95,7
106,2/95,6
106,5/95,9
Efficiency at 30% at 30°C (condensation) Hi/Hs
%
107,7/97
108,1/97,3
108/97,3
108/97,3
Efficiency at 30% at 47°C Hi/Hs
%
97,7/88
97,8/88,1
97,8/88,1
97,8/88,1
Minimum calorific flow rate efficiency (60/80°C) Hi/Hs
%
97,6/87,9
97,8/88,1
97,8/88
97,7/88
Efficiency rating (dir. 92/42/EEC)
stars
****
****
****
****
Sedbuk class
class
A/90,1
A/90,1
A/90,1
A/90,1
Loss when stopped (∆T = 50°C)
%
Loss of burner gas when operating
%
2
1,9
2
2
Available air pressure
Pa
100
100
90
100
NoX class
class
5
5
5
5
Flue gas temperature (G20) (80°C-60°C)
°C
61
62
62
63
CO2 content (G20) (80°C-60°C)
%
9
9,3
9,3
9,3
CO content (0%O2) (80°C-60°C)
ppm
93
143
134
99
O2 content (G20) (80°C-60°C)
%
4,5
4
4
4
Maximum flue gas flow (G20) (80°C-60°C)
Kg/h
29,7
41,6
48
55,2
Excess air (80°C-60°C)
%
27
23
23
23
Expansion chamber inflation pressure
bar
1
1
1
1
Maximum heating pressure
bar
3
3
3
3
Expansion chamber capacity
l
6,5
6,5
6,5
6,5
Min/max heating temperature (high temperature range)
°C
35/ 82
35/ 82
35/ 82
35/ 82
Min/max heating temperature (low temperature range)
°C
20/ 45
20/ 45
20/ 45
20/ 45
Domestic hot water max/min temperature
°C
40/60
40/60
40/60
40/60
Power supply frequency/voltage
V/Hz
230 / 50
230 / 50
230 / 50
230 / 50
Total electrical power absorbed
W
80
78
83
82
Minimum ambient temperature for use
°C
5
5
5
5
Protection level for the electrical appliance
IP
X5D
X5D
X5D
X5D
Weight
kg
35
35
35
36