Appliance technical specications
Legend :
1.
Cold water inlet/hot water usage point (following
direction of installation),
2.
Cold water inlet/hot water usage point (following
direction of installation),
3.
Primary inlet/Primary outlet (following direction of
installation),
4.
Primary inlet/Primary outlet (following direction of
installation),
5.
Protech System (protection against corrosion),
6.
Magnesium Startup Anode,
7.
Temperature sensor,
8.
Polyurethane insulation,
9.
Coil Exchanger,
10.
Recirculation (except 80 L BCH).
BCH 80 L 120 L 160 L 200 L
Coil
Coil
capacity Ltr 3,15 4,40 4,40 6,25
C
oil surface m
2
0,5 0,7 0,7 1
Exchanger output (En 15332) kW
Stable
position 10,3 13,9 15,5 21,0
Wall
position 9,6 13,3 7,5 20,7
Exchanger
output (EN 12897) kW
Stable position 8,4 11,8 14,7 19,2
Wall
position 7,4 10,1 11,3 16,0
Coil
resistance mbar
Stable
position 16 33 7 41
Wall
position 16 23 26 34
M
ax. working pressure (EN 12897) bar 10 10 10 10
The power consumption data in the table and the other information given in the Product Data Sheet
(Annex A attached to the product) are defined in relation to EU Directives 812/2013 and 814/2013.