EasyManua.ls Logo

Ariston CLAS HE SYSTEM 18 - First Igniton Operation

Ariston CLAS HE SYSTEM 18
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
commissioning
FIRST IGNITION OPERATION
1. Check the electrical supply.
Complete . . . . . . . . . . . . . . . . . . .
Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installer . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Check the type of gas and
change the gas if necessary.
Complete . . . . . . . . . . . . . . . . . . .
3. Check the gas tightness.
Complete . . . . . . . . . . . . . . . . . . .
4. Measure the gas inlet/
standing pressure
Complete . . . . . . . . . . . . . . . . . . .
5. Check the ue installation.
(See Connecting the ue)
Complete . . . . . . . . . . . . . . . . . . .
6. Fill the installation and
ush. See page 28
Complete . . . . . . . . . . . . . . . . . . .
7. Check the hydraulic water
tightness.
Complete . . . . . . . . . . . . . . . . . . .
8. Spin the pump.
Complete . . . . . . . . . . . . . . . . . . .
9. Purge air by pressing ESC
button for 5 sec. & manually
vent the exchanger
Complete . . . . . . . . . . . . . . . . . . .
10. Change the language in
the display (if necessary).
Page 33.
Complete . . . . . . . . . . . . . . . . . . .
11. Set the hour, and the date.
See page 33
Complete . . . . . . . . . . . . . . . . . . .
12. Set the heating power. See
page 33
Complete . . . . . . . . . . . . . . . . . . .
13. Balance the central
heating circuit.
Complete . . . . . . . . . . . . . . . . . . .
14. Measure the gas inlet
working pressure.
Complete . . . . . . . . . . . . . . . . . . .
15. Check the combustion
rate. See page 34
Complete . . . . . . . . . . . . . . . . . . .
16. Gas rate the appliance
Complete . . . . . . . . . . . . . . . . . . .
17. Explain to the end user the
working of the boiler and
controls
Complete . . . . . . . . . . . . . . . . . . .

Related product manuals