51
MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS PREMIUM
3.11 TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
TEMPERATURE SENSORS & OVERHEAT THERMOSTAT
Tools
Time
5 min
1
Remove the clip and the
temperature sensor or
overheat thermostat together
Unplug the electrical
connectors
IMPORTANT!!!! Do not use conducting paste for the contact sensors because it will alter the resistance value.
TEMPERATURE (°C) RESISTANCE (kOmh)
0 27
10 17
20 12
25 10
30 8
40 5
50 4
60 3
70 2
80 1
,
5
3.12 MANUAL AIR VENT
MANUAL AIR VENT
Tools
Time
5 min
1
Remove the clip and lift the manual air vent from the
exchanger
Page. 13 of 20