EasyManua.ls Logo

Ariston CLAS HE SYSTEM 18 - Page 48

Ariston CLAS HE SYSTEM 18
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS PREMIUM
3.4 PRIMARY WATER PRESSURE SENSOR
PRIMARY WATER PRESSURE SENSOR
Tools
Time
5 min
1
Drain boiler (see 3.2). Remove the fixing clip,
unplug the electrical connector and lift the
sensor from the assembly
3.5 PUMP
PUMP
Tools
Time
10 min
1
Drain boiler (see 3.2). Remove
the clip and the two screws
Disconnect the pipe and then
move the pump to the right
disengage
Remove the pump
2
Remove the sensor (see 3.4) Remove the AAV (see 3.3)
Page. 10 of 20