15
B063
Removing the overheat thermostat
1.
Disconnect the overheat thermostat electrical
connections N1 (FIG. 1.54);
2. Then remove the thermostat from its mounting by
releasing the securing clip (FIG. 1.55).
Removing the heating temperature sensor (N.T.C.)
1.
Pull off the electrical connector P1 and unscrew the
sensor probe using a suitable spanner (FIG. 1.56).
FIG. 1.54
FIG. 1.55
Removing the D.H.W. temperature sensor (N.T.C.)
1.
Pull off the electrical connector Q1 and unscrew the
sensor probe using a suitable spanner (FIG. 1.57).
FIG. 1.57
Removing the divertor valve actuator
1. Unplug the electrical connector R1 (FIG. 1.58);
2. Release the retaining clip S1 and remove the divertor
valve actuator.
FIG. 1.58
Removing the D.H.W. flow switch
1. Unplug the electrical connector T1 (FIG. 1.59);
2. Release the retaining clip V1 and remove the D.H.W.
flow switch.
FIG. 1.59
N1
P1
Q1
S1
R1
FIG. 1.56
T1
V1
80.eps