96 /
MENU
SUB-MENU
PARAMETER
DESCRIPTION RANGE FACTORY SETTINGS
12 2 5 Pro-Tech anode active OFF - ON OFF
12 2 6 EM Antiblocking Function Enable OFF - ON OFF
12 3 Central Heating
12 3 0 CH pump prerun time 30 - 255 sec. 30 sec.
12 3 1 Time for prerun new attempt 0 - 100 sec. 90 sec.
12 3 2 CH Pump Overrun 0 - 15 min. ; 16 = always active 3 min.
12 3 3 Pump Speed Control
Low Speed
High Speed
Modulating
Modulating
12 3 4 Delta T Pump Setpoint 5°C - 20°C 5°C
12 3 7 Max PWM Pump Min PWM pump - 100% 100%
12 3 8 Min PWM Pump 20% - Max PWM pump 40%
12 3 9 Floor drying Flow Set Point T 25°C - 60°C 55°C
12 4 Cooling
12 4 0 Cooling mode activation
Not active
Active
Not active
12 4 1 Cooling anticycling time 0 - 10 min 3 min.
12 4 2 Cooling FlowT HP Oset 0°C , -10°C -2°C
12 5 Domestic Hot Water
12 5 0 DHW Comfort Setpoint T 35°C - 65°C 55°C
12 5 1 DHW Reduced Set Point T 35°C - DHW Comfort Tenperature 35°C
12 5 2 Comfort Function
Disabled
Time based
Always Active
Always Active
12 5 3 Tank charge mode
Standard
Only HP
Fast
Standard
12 5 4 Thermal Cleance Function OFF - ON ON
12 5 5 Thermal Cleance start time [hh:mm]
[00:00-24:00] 01:00
12 5 6 Thermal Cleance frequency
1 ÷ 30 days 30 days
12 5 7 DHW delay timer 10 ÷ 120 min 30 min
12 5 8 Soglia DHW Release Integral 15 ÷ 200 °C*min 60°C*min
12 6 Manual Mode - 1
9 6 0 Manual mode activation OFF - ON OFF
12 6 1 HP circulator control
OFF
Low Speed
High Speed
OFF
12 6 2 Diverter valve control
DHW
CH
DHW
12 6 3 Diverter valve COOLING
CH
COOLING
CH
12 6 4 Auxiliary circulator OFF - ON OFF
12 6 5 Output AUX 1/2 contact OFF - ON OFF
12 6 6 Force Hp Heat OFF - ON OFF
12 6 7 Force Hp Cool OFF - ON OFF
12 6 8 Force WHB OFF - ON OFF
12 6 9 Anode output OFF - ON OFF
12 7 Manual Mode - 2