MENU
SUB-MENU
PARAMETER
DESCRIPTION RANGE FACTORY SETTINGS
12 16 EM Diagnostics - 1 Input
12 16 0 Energy Manager Status
Stand-by
Antifreeze Cycle
Heating Cycle
Heating Temp. Reached
DHW Cycle
Thermal Cleanse Function
Air Purge Function
Chimney Function
Floor drying cycle
No Heat Generation
Manual Mode
Error
Initialization
O
Cool Mode
DHW Antifreeze
Photovoltaic Integration
Dehumidification
Pump Down
Defrost
Buer Heating + DHW Serving
Buer Cooling + DHW Serving
only reading
12 16 1 CH Flow Set T only reading (°C)
12 16 2 CH Flow Temperature only reading (°C)
12 16 4 DHW Storage Temperature only reading (°C)
12 16 5 Pressure Switch only reading (bar)
12 16 6 HV Input 1 Open - Closed only reading
12 16 7 HV Input 2 OFF - ON only reading
12 16 8 HV Input 3 OFF - ON
12 16 9 AUX Input 1 Open - Closed
12 17 EM Diagnostics - 2 Output
12 17 0 CH Circulator Status OFF - ON only reading
12 17 1 HC Pump 2 OFF - ON only reading
12 17 2 Diverter Valve (CH/DHW)
DHW
CH
only reading
12 17 3 Diverter Valve 2 (CH/Cooling)
CH
COOLING
12 17 4 EM Anode
Not active
Active
only reading
12 17 5 AUX Output 1 (AFR) Open - Closed only reading
12 17 6 AUX Output 2 Open - Closed only reading
12 18 Error History
12 18 0 Last 10 Errors
only reading
12 18 1 Reset Error List Reset? OK=Yes, esc=No
12 19 Reset Menu
12 19 0 Reset Factory Settings Boiler
19 Connectivity
19 0 Connectivity Settings
19 0 0 ON/OFF Wi-Fi Network
19 0 1 Network configuration
19 0 3 Internet Time
19 1 Connectivity Info