EasyManua.ls Logo

Ariston NIMBUS COMPACT S NET - Data Plates and Refrigerant Data; Unit Data Plate Information; Refrigerant Specifications

Ariston NIMBUS COMPACT S NET
100 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
97 / GB
External unit data plateInternal unit data plate
1
2
3
7 8 9 10
11
14
16 17
19
18
15
12 13
4 5 6
Legend:
1. Homologation
2. Certi cation
3. Model
4 Performance Ratings heating circuit
5 Cooling date
6 Performance Ratings cooling circuit
7 Type of oil in the refrigerant circuit
8 Refrigerant type - load of the refrigerant
9 GWP
10 CO
2
Equivalent (t)
11 Electrical data
12 Electrical protection
13 Maximum electric power
14. Maximum pressure refrigerant circuit
15. Minimum pressure refrigerant circuit
16 Plant of manufacturing
17 Protection rating
18 Certicate
19 Contact address
1
2
3
4
5
9
10 11
MAX MIN
12
Legend:
1. Brand
2. Manufacturer
3. Appliance model - Serial number
4. Commercial reference
5. Certication number
9. Electrical data
11. Maximum heating pressure
12. Nominal power of heating
elements
Refrigerant data
40 S EXT 50 S EXT 70 S
70 S-T EXT
90 S
90 S-T EXT
110 S
110 S-T EXT
Refrigerant type
R410A R410A R410A R410A R410A
Load of the refrigerant
[g] 2300 2300 3080 4300 4300
GWP
2088 2088 2088 2088 2088
CO
2
Equivalent (t)
4,8 4,8 6,4 8,9 8,9
NOTE:
In compliance with 811/2013 EU Regulation, the outdoor unit which is part of the system purchased carries a label related to a specific
configuration; in case the system you chose does not match the one on the label, it is possible to retrieve the appriopriate label at www.
ariston.co.uk or by calling our Customer Centre at +44 0333 240 8777.

Table of Contents

Related product manuals