72 / GB
17.7.2 Force Hp Cool
Activate the heat pump in cooling mode
17.7.3 Rating Heating Mode
17.7.4 Rating Cooling Mode
17.7.5 Fixed compressor frequency
De ne the compressor frequency during the working mode
of the heat pump selected by the parameters 17.7.1 or 17.7.2.
In manual mode the heat pump keeps the protection logics
active, therefore the compressor frequency might be di erent
from the set one.
Turn the knob and select:
17.8 Test & Utilities
Press the OK button to con rm.
Turn the knob and select:
17.8.0 Air-purge function
Active the air purge cycle of the system; the air purge duration
is 18 minutes.
Press the OK button to con rm. Turn the knob and select:
17.8.1 Floor drying cycle
de ne the oor drying cycle mode:
- 0. OFF
- 1. Functional Heating
( oor drying done at xed temperature of 55°C for 6 days)
15
20
25
30
35
40
45
50
55
60
0 1 2 3 4 5 6 7 8 9 1 0
- 2. Curing Heating
( oor drying done with variable temperature from 25°C to
55°C according to the pro le reported in the picture below
for 18 days)
15
20
25
30
35
40
45
50
55
60
0 2 4 6 8 1 0 12 14 16 18 20
- 3. Functional Heating + Curing Heating
( oor drying done at xed temperature of 55°C for 6days and
then with variable temperature from 25°C to 55°C for the fol-
lowing 18 days)
15
20
25
30
35
40
45
50
55
60
0 5 1 0 15 20 25 30
- 4. Curing Heating + Functional Heating
( oor drying done with variable temperature from 25°C to
55°C for the rst 18 days and then at xed temperature of
55°C for the following 6 days)
15
20
25
30
35
40
45
50
55
60
0 5 1 0 15 20 25 30
- 5. Manual
( oor drying done at the setpoint temperature set by the pa-
rameter 17.3.9)
17.8.5 Refrigerante Recover Cycle
Activate this function to recover the refrigerant gas before eve-
ry maintenance operation on the refrigerant circuit.
Turn the knob and select:
17.9 Energy Manager Statistics
17.10 HP Diagnostics - 1
17.11 HP Diagnostics - 2
17.12 HP Diagnostics - 3
17.13 HP Diagnostics - 4
Displays the characteristic information of the heat pump (tem-
peratures, water ow switch status, HP status, etc).
Turn the knob and select:
17.14 Energy Manager Diagnostics -1 Input
Displays the values of the system board inputs
Turn the knob and select:
17.15 Energy Manager Diagnostics - 2 Output
Displays the values of the system board outputs
Turn the knob and select:
17.16 Error History
Last 10 Errors.
Turn the knob and select:
17.17 Reset Menu
Reset Factory Settings.
Temperature °C
Period (days)
Temperature °C
Period (days)
Temperature °C
Period (days)
Temperature °C
Period (days)