EasyManua.ls Logo

Ariston TVM63X NA - Timer Sequence Charts

Ariston TVM63X NA
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indesit Company
12 of 19
Service Manual UK English
Reversing Timer Sequence Chart
Switch Ratings
CONTACT / TERMINAL
RATING COMPONENT
SWITCHED
MAX.
CURRENT
Invensys EC
C3 - C2 16(4)A TIMER MOTOR <1A
C3 - C1 16(4)A TIMER MOTOR <1A
A1 - A3/A4 16(4)A MOTOR & HEATER 10A
B3/B4 - B1 16(4)A HEATER 9.2A
3
140 mins
130 mins
120 mins
110 mins
100 mins
90 mins
80 mins
70 mins
60 mins
50 mins
40 mins
30 mins
20 mins
7.5 mins
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
2.5 min
2.5 min
2.5 min
Auto
C3 - C1 (C3 - C4)
Timed
C3 - C2 (C3 -C5)
stat select
A9 - A11 (A1 - A2)
*1 *1 *1
*1
Timer & Motor
A1 - A3 (B 3 - B4)
Buzzer
B10 - B11 (B2 - B1)
Heater
B3 - B1 (A4 - A5)
Note *1: the programme cam should advance to the next step before the timer stops
Main Timer
Sequence Chart
switch
switch
no.
1 2 3 4 5 6 7 8 9 10 1112 13 14 15 16 17 18 19 2021222324252627282930313233343536373839404142434445464748495051525354555657585960
1 to 2 secs - > < - - - - - - - 148 seconds +/-2 - - - - - - - - - - - >: < - 1 to 2 seconds
motor cw a - a1
mo tor a cw a - a0
<------------------------300 seconds--------------------------->