Note: Electrical wiring must be carried out
by a registered electrical contractor.
Ensure electricity is switched off at the mains
before installing or maintaining any light fitting
Where to fit your Arlec Dual Floodlight
with Sensor
Ideally the light should be mounted 2.4 metres (8ft)
above the area to be scanned (Refer Fig.1) or on
an eave.
Although this product is weatherproof it is
preferable to mount your Arlec Dual Floodlight with
Sensor in a sheltered or semi-sheltered location.
To avoid damage to unit – do not
aim the sensor
towards the sun.
Fig. 1
Best
sensitivity
Sensor can be angled above
animal height to avoid
nuisance triggering
Installation Instructions
Dual Floodlight with Sensor
Important! Please read these instructions carefully.
MAL413
To avoid nuisance triggering, the sensor should be
directed away from heat sources such as barbecues,
airconditioners, other outside lighting, flue vents and
moving cars.
Do not aim towards reflective surfaces such as
smooth white walls, swimming pools etc.
The scanning specifications (15 metres at 110° scan)
may vary slightly depending on the mounting height
and location. (Refer Fig. 1 and 2). The detection range
of the unit may also alter with temperature change.
Before selecting a place to install the Arlec Dual
Floodlight with Sensor, you should note that
movement across the scan area is more effective
than movement directly toward or away from the
sensor. (Refer Fig. 3A).
If movement is made walking directly towards or
away from the sensor and not across, the apparent
detection range will be substantially reduced
(Refer Fig. 3B).
3m (10ft)15m (55ft) 6m (20ft)
-6°
-27°0°
2.4m (8ft)
Ideal
mounting
height
110°
Fig. 2
Fig. 3A
Fig. 3B
Reduced
sensitivity

Questions and Answers

  • J
    Jared BrockAug 11, 2025
    What to do if my Arlec Flood Light stays on all the time?
    • M
      Marissa WilliamsAug 12, 2025
      If your Arlec Flood Light remains on, there are a few potential causes: 1. The sensor might be in Manual Mode. To resolve this, switch the light OFF for at least 15 seconds, and then return it to the ON position. 2. The sensor could be continuously triggered by something like trees, pools, or flues. Try redirecting the sensor away from these elements. 3. Incorrect wiring could also be the issue. Double-check the wiring to ensure it's correct.
  • B
    Brian BoydAug 20, 2025
    How to improve the sensitivity of my Arlec MAL413 Flood Light?
    • B
      bdaviesAug 20, 2025
      If your Arlec Flood Light has poor sensitivity, it might be because movement is directly toward or away from the sensor. Try redirecting the sensor. Also, higher ambient temperatures can affect sensitivity, so redirecting the sensor might help in this case as well.
  • S
    Steven OrtizOct 31, 2025
    Why does my Arlec Flood Light keep turning on by itself?
    • A
      Arthur SimmonsOct 31, 2025
      Your Arlec Flood Light might be turning on for several reasons: * Heat from the bulb may be activating the sensor. Try adjusting the lamp holders to ensure there's at least a 40mm gap between the PAR38 bulb and the sensor head. * Heat sources like air conditioners, vents, heater flues, barbecues, other outside lights, or moving cars could be triggering the sensor. Adjust the sensor's direction to avoid these sources. * Animals or birds, such as possums or pets, might be setting it off. Redirecting the sensor might help. * On/off switching of electric fans or lights on the same circuit could be causing interference. Consider replacing a faulty switch, replacing noisy fluorescent tubes or starters, or connecting the floodlight to a separate circuit. * Reflection from a swimming po...

Summary

Installation Instructions

Where to Fit the Floodlight

Guidance on optimal placement for the dual floodlight with sensor, considering height and surroundings.

Wall Mounting

Instructions for mounting the floodlight on a wall, including marking screw holes.

Eave Mounting

Instructions for installing the floodlight under an eave, ensuring correct sensor direction.

Wiring the Floodlight

Details on wiring the dual floodlight to its own switch, with safety precautions.

Fitting the Floodlight and Globes

Steps for mounting the floodlight after wiring and fitting globes, ensuring weatherproofing.

Adjusting Sensor and Lampholders

Guidance on adjusting the sensor and lampholder angles for optimal detection.

Powering Up and Testing

Steps for restoring power and performing initial functional tests and sensor calibration.

Automatic and Manual Modes

Explanation of automatic operation and how to manually override the mode.

Specifications

Maintenance of the Floodlight

Routine maintenance advice for keeping the sensor lens clean and ensuring proper functioning.

Reducing Detection Area

Method to reduce the sensor's 110° detection range by applying tape to the lens.

Trouble Shooting Guide

Arlec Guarantee

Proof of Purchase

Requirement to retain purchase receipt for warranty claims.

Arlec MAL413 Specifications

General IconGeneral
Model NumberMAL413
Power30W
Lumen Output2400 lm
Color Temperature5000K
IP RatingIP65
MaterialAluminium
Voltage240V
Lamp TypeLED
ColourBlack
Weight1.2 kg
Beam Angle120°