11
INSTALLING & CLEANING FOAM SLEEVE FILTER
43 5
2
o
Installing Foam Sleeve Filter
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Remove power head and place in upside down position. Follow instructions to remove cartridge lter.
3. Carefully slide foam sleeve lter down over the lter cage making sure the whole cage is covered. (g. 2 & 3)
4. Replace the power head on to the container.
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve lter. (g. 4)
2. Use a mild soap and water solution to wash foam sleeve lter and rinse with clean water. (g. 5)
3. Allow lter to air dry before installing and using again.
Symptom Possible Causes Corrective Action
Vacuum will not operate 1) No power supply.
1) Check power supply – cord, breakers,
fuses.
2) Faulty power cord.
2) Unplug and check the power cord. If
damaged, have it repaired by a professional.
3) Container full. 3) Empty container.
Dust comes from motor cover.
1) The cartridge lter is missing or
damaged.
1) Attach or replace the cartridge lter.
Reduced efciency and motor/
speed vibration.
1) There is a blockage in the nozzle,
hose, or the vacuum inlets. Or the dust
lter is blocked by ne dust.
1) Check nozzle, hose and container inlets
for blockage. Take off the lter and clean it.
Or install new lter.
TROUBLESHOOTING
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING