EasyManua.ls Logo

Armstrong A96UH2E User Manual

Armstrong A96UH2E
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
507581-04 Issue 1933 Page 1 of 59
This manual must be left with the homeowner for future reference.
INSTALLATION INSTRUCTIONS
A96UH2E
Warm Air Gas Furnace
Upow/Horizontal Left Air Discharge
Direct Vent & Non-Direct Vent
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
WARNING
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
CAUTION
Save these instructions for future reference
(P) 507581-04
*P507581-04*
Manufactured By
Allied Air Enterprises LLC
A Lennox International, Inc. Company
215 Metropolitan Drive
West Columbia, SC 29170
Table of Contents
Unit Dimensions ............................................................2
Parts Arrangement.........................................................3
A96UH2E Gas Furnace .................................................4
Shipping and Packing List .............................................4
Safety Information .........................................................4
General ..........................................................................6
Combustion, Dilution & Ventilation Air ...........................7
Installation ...................................................................10
Filters ...........................................................................14
Duct System ................................................................14
Venting.........................................................................16
Condensate Piping ......................................................33
Gas Piping ...................................................................37
Electrical ......................................................................40
Blower Performance ....................................................49
Unit Start-Up ................................................................52
Other Unit Adjustments................................................55
Service.........................................................................55
Planned Service ..........................................................57
Repair Parts List ..........................................................58
Question and Answer IconNeed help?

Do you have a question about the Armstrong A96UH2E and is the answer not in the manual?

Armstrong A96UH2E Specifications

General IconGeneral
BrandArmstrong
ModelA96UH2E
CategoryFurnace
LanguageEnglish

Summary

Installation Instructions

Unit Dimensions

Parts Arrangement

A96UH2E Gas Furnace

Shipping and Packing List

Lists items included in the furnace packaging and instructions for checking shipping damage.

Safety Information

Provides critical warnings and cautions regarding installation and operation safety.

Building Codes

Use of Furnace as a Construction Heater

General Installation Guidelines

Combustion, Dilution & Ventilation Air

Installation

Setting Equipment

Instructions and warnings for physically placing and leveling the furnace unit.

Shipping Bolt Removal

Details on removing shipping bolts from the blower motor legs before operation.

Return Air Guidelines

Removing the Bottom Panel

Horizontal Applications

Platform Installation of Horizontal Unit

Suspended Installation of Horizontal Unit

Filters

Duct System

Supply Air Plenum

Return Air Plenum

Pipe & Fittings Specifications

Canadian Applications Only

Venting

Exhaust Piping

Vent Piping Guidelines

Intake Piping

Condensate Piping

Gas Piping

Electrical

Integrated Control DIP Switch Settings

Field Wiring Applications With Conventional Thermostat

Blower Performance

Unit Start-Up

Turning Off Gas to Unit

Failure to Operate Troubleshooting

Heating Sequence of Operation

Gas Pressure Adjustment

Supply Pressure Measurement

Manifold Pressure Measurement

Proper Combustion

High Altitude Information

Other Unit Adjustments

Service

Blower

Instructions for checking the blower wheel for debris and cleaning it.

Filters

Guidance on inspecting, cleaning, or replacing air filters for optimal furnace operation.

Exhaust and Air Intake Pipes

Instructions to check exhaust and air intake pipes and connections for tightness and blockages.

Winterizing and Condensate Trap Care

Cleaning Heat Exchanger

Cleaning the Burner Assembly

Planned Service

Repair Parts List

Massachusetts Requirements

Related product manuals