506303-01 Page 1 of 40Issue 0938
Save these instructions for future reference
INSTALLATION INSTRUCTIONS
G2D93CT, G2D93CU, G2D95CT, & G2D95CU
High Efficiency Multiposition Gas Furnace
with System Sentry™ Control System
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional information, consult a qualified installer, service agency,
or the gas supplier.
WARNING
Do not store combustible materials, including gasoline and
other flammable vapors and liquids, near the furnace, vent
pipe, or warm air ducts. The homeowner should be
cautioned that the furnace area must not be used as a
broom closet or for any other storage purposes. Such uses
may result in actions that could cause property damage,
personal injury, or death.
WARNING
This furnace is not approved for installation in a mobile
home. Do not install this furnace in a mobile home.
Installation in a mobile home could result in actions that
could cause property damage, personal injury, or death.
WARNING
The installation of the furnace, wiring, warm air ducts, venting, etc. must conform to the requirements of the National Fire
Protection Association; the National Fuel Gas Code, ANSI Z223.1/NFPA No. 54 (latest edition) and the National Electrical
Code, ANSI/NFPA No. 70 (latest edition) in the United States; CSA B149.1 (latest edition) Natural Gas and Propane Installation
Codes and the Canadian Electrical Code Part 1, CSA 22.1 (latest edition) in Canada; and any state or provincial laws, local
ordinances (including plumbing or wastewater codes), or local gas utility requirements. Local authorities having jurisdiction
should be consulted before installation is made. Such applicable regulations or requirements take precedence over the
general instructions in this manual.
IMPORTANT
Manufactured By
Allied Air Enterprises Inc.
A Lennox International Inc. Company
215 Metropolitan Drive
West Columbia, SC 29170
TABLE OF CONTENTS
SAFETY ........................................................ 2
INSTALLATION ............................................. 3
START-UP................................................... 26
OPERATION ............................................... 27
MAINTENANCE .......................................... 32
CONTROL DIAGNOSTICS ......................... 33
REPAIR PARTS .......................................... 34
WIRING DIAGRAMS................................... 35
*506303-01*
Question and Answer IconNeed help?

Do you have a question about the Armstrong G2D95CT and is the answer not in the manual?

Armstrong G2D95CT Specifications

General IconGeneral
BrandArmstrong
ModelG2D95CT
CategoryFurnace
LanguageEnglish

Summary

IMPORTANT SAFETY INFORMATION

INSTALLATION

Location

Proper placement for optimal furnace operation and performance.

Clearances

Combustion and Ventilation Air

Venting

Category IV Furnace Limitations

Vent Pipe and Kit Specifications

Sidewall Vent Terminal Clearances

Direct Vented Furnaces

Clearance requirements for direct vent sidewall terminals.

Sidewall Vent Terminal Clearances (Non-Direct Vented Furnaces)

Upflow Venting Installation

Horizontal Venting Installation

Condensate Disposal

Gas Piping Connection

Electrical Wiring

Heating Mode and Airflow Adjustment

Setting heating mode and adjusting blower speeds for optimal temperature rise.

START-UP

MAINTENANCE

CONTROL DIAGNOSTICS

MASSACHUSETTS ONLY - Venting Requirements