ALEXA Mini SUP 6.1 Page 6 of 11
Release Notes All data subject to change without further notice.
D. Known Issues
Known Issues Fixed in SUP 6.1
Following known issues have been resolved in the SUP 6.1 release:
The Waveform exposure tool is silently disabled when output processing is set to ALEXA Classic 709
ALEXA Classic 709 output processing while shooting HDR content does not work with the waveform exposure tool and
is silently disabled. User buttons and the EXP button on the MVF-1 viewfinder will have no effect.
Start recording from playback
Starting a recording directly from playback may not work. In this case a second press of the record button is necessary.
Incorrect remaining time displayed in interval recording
Using higher capacity CFast 2.0 cards for interval recording may cause wrong remaining time display.
Time zone and daylight saving time are set to default with the SUP update.
Please make sure to set time zone and daylight saving time after the SUP update.
Known Issues in SUP 6.1
This is a list of known issues for the SUP 6.1 software package.
Accessories
Record Start/Stop on Canon HJ18 B4 lens
In case the start/stop function on the Canon HJ18 B4 lens is not working with the ARRI B4 Mount and connected
Hirose cable, please execute a "Reset all" on the lens.
EXT Sync
Warning message for camera count is not updated while active
While the warning message for the camera count is displayed, changes in the camera count will not be updated. Just
close the warning message for an update.
Changing SDI settings while running off sync speed
The SDI outs might not be in sync to each other anymore when SDI settings (SDI frame rate, SDI format and/or SDI
image) are changed while the cameras are running off speed (sensor fps != project fps) in EXT sync mode. In this case
change the sensor fps setting back and forth on the master camera to re-establish SDI out sync.
False alerts with slave cameras connected but not yet configured
False alert states are issued when slave cameras are connected to a master camera but are not yet configured as slave
camera. When setting up an EXT sync cluster, first enable all slave cameras and master last.
Frame Grab
Frame grabs are not supported at paused playback of interlaced S16 or HD clips
In order to perform a frame grab, grab the frame during playback at the desired position.
Frame grab with CAP over WiFi fails
When activating a frame grab with CAP over a WiFi connection, the frame grab may fail. A CAP frame grab over a
Ethernet connection works fine.
Frame grabs from ARRIRAW playback
Frame grabs taken from ARRIRAW playback may exhibit differences in pixel brightness on the edges of the frame.

Other manuals for ARRI ALEXA Mini

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ARRI ALEXA Mini and is the answer not in the manual?

ARRI ALEXA Mini Specifications

General IconGeneral
Sensor TypeALEV III CMOS
Dynamic Range14+ stops
Recording FormatsARRIRAW, ProRes
Power Input10.5-34 V DC
Base SensitivityEI 800
Lens MountPL mount
Weight2.3 kg
ISO Range160 to 3200
Frame Rates0.75 - 200 fps (depending on recording format and sensor mode)
Dimensions185 mm x 125 mm x 140 mm
Power ConsumptionApprox. 50 W
OutputsHD-SDI
Sensor SizeSuper 35 format