Brouwmarkt BV, Markerkant 1111, 1316 AE Almere
www.braumarkt.com
• Do not run the pump without water. The boiler must contain water before switching on the pump.
• Use the pump during the mashing process.
• Use the blue valve on the circulation pipe to adjust the flow rate for correct circulation speed.
If the pump speed is too fast, the grain basket (8) will overflow down the central pipe, and the
bottom of the boiler may run dry and cause ingredients to burn and overheat the element.
• The blue valve, on the circulation pipe, in horizontal position closes the ball valve, and in vertical positi-
on opens the ball valve.
• Switch off the pump when you close the blue valve for longer than 5 seconds.
• Always close the blue valve and switch off the pump before removing the curved pipe (11).
• Do not run the pump during wort boiling.
• Do not use the pump for pumping the wort after cooling, as the pump inlet does not have a filter. This
can cause brew debris to enter the pump, potentially blocking and damaging the system..
• Use the clip bind to attach the bazooka filter (12) on the male thread inside the Easybrew. Tighten by
using a screw driver (see pictures below)..
Use of the pump
Assembling the bazooka lter